M800S/M80 Series Connection and Setup Manual
28 Device Open Parameter Screen
Display items
Display items
(1)
Parameter No.
(2)
Device allocation
(3)
Data type
(4)
Number of data
Details
Display the parameter No.(maximum of 100).
Set the head device which designates the divided area.
- It is possible to designate the device allocation which overlaps with
other groups.
- When "0" is set to the device allocation, it clears the settings (data
type, display format etc.) of the target group.
- When an odd number address is set for the device allocation,
DWORD cannot be designated for the data type.
Set the data type (BYTE, WORD, DWORD, WORD(BIT)) of the
allocation area.
BYTE: The area is secured per 1-byte.
WORD: The area is secured per 2-byte.
DWORD: The area is secured per 4-byte.
WORD(BIT): The area is secured per 2-byte.
DWORD cannot be designated when the device allocation is an odd
number address.
BIT format is valid for the display format when WORD(BIT) is
designated.
The data type can also be designated by pressing the menu [BYTE],
[DWORD], or [WORD(BIT)].
Set the number of data in the allocation area.
Number of data available to designate varies depending on the
designated data type.
(Note) When the number of data is "0", the target group will be invalid.
(Example)
Device allocation: R8400
Data type: DWORD
Number of data: 100
R8400
DWORD
R8402
DWORD
R8598
DWORD
445
400byte
Setting range
-
R8300 to R9799
R18300 to R19799
R28300 to R29799
0
0:WORD
1:DWORD
2:BYTE
3:WORD(BIT)
0 to 3000
It depends on the
device allocation
and the data type.
IB-1501269-F