4 General Specifications
[LED : FCU8-DX651]
(1)
No.
Name
H1
Safety relay output SYR00 status
H2
Safety relay output SYR01 status
(1)
H3
Safety relay output SYR02 status
H4
Safety relay output SYR03 status
(2)
ALM
RIO communication error
Energization status of 24VDC input of
(3)
DCIN
DCIN connector
(4)
FUSE Fuse status
IB-1501269-F
(2)
(3)
(4)
Function
Color
Green
Green
Green
Green
Red
Green
Green
112
Status
Normal
At fault
Lit
Not lit
Not lit when a relay has been blown out.
Lit
Not lit
Not lit when a relay has been blown out.
Lit
Not lit
Not lit when a relay has been blown out.
Lit
Not lit
Not lit when a relay has been blown out.
Lit when RIO communication error has
Not lit
Lit
occurred.
Lit
Not lit
Lit when a current is applied.
Lit
Not lit
Not lit when a fuse has been blown out.