INTERNATIONAL
ELECTRICAL
REQUIREMENTS
March 2014
Units being used outside the United States may not be shipped with the
power cord attached to the unit because of the different wiring codes.
The fryers are available from the factory wired for 200, 240, 380 and
415 volts, 3 phase, 50 Hertz service. A terminal block is mounted
inside the fryer for the cable wiring.
CE units require a minimum wire size of 4mm to be wired to
the terminal block. If a flexible power cord is used, it must be
HO7RN type.
The supply power cords shall be oil-resistant, sheathed flexible
cable, no lighter than ordinary polychloroprene or other
equivalent synthetic elastomer-sheathed cord.
It is recommended that a 30 mA rated protective device such
as a residual current circuit breaker (RCCB), or ground fault
circuit interrupter (GFCI), be used on the fryer circuit.
(FOR EQUIPMENT WITH CE MARK ONLY!) To prevent electric
shock hazard this appliance must be bonded to other appliances or
touchable metal surfaces in close proximity to this appliance with an
equipotential bonding conductor. This appliance is equipped with an
equipotential lug for this purpose. The equipotential lug is marked
with the following symbol