Henny Penny PXE-100 Operator's Manual page 54

Velocity series pressure fryer
Hide thumbs Also See for PXE-100:
Table of Contents

Advertisement

4-4.
FILTER CONTROL
(CONT.)
March 2014
Quick Filter Settings
These parameters control the Quick Filter operation, which
activates automatically after a cook cycle, and may also be
initiated manually from the Filter Menu.
The Quick Filter has three basic steps:
1.
DROP: Opens the drain and drops the oil level by a certain
amount. Depending on settings, could drop the oil level just a
few inches during this phase, or could drain the entire pot.
2.
FILTER: Runs the filter pump with the drain partially open
for a given time, pumping the oil through the filter paper
to clean the oil. This operation typically holds a relatively
constant oil level in the pot.
3.
FILL: Closes the drain fully and runs the filter pump to
refill the pot. Watches for a temperature rise on the upper
temperature probe (level probe) to indicate that the pot has
refilled. Runs the pump a bit longer to get the last of the oil
out of the filter pan, then turns the pump off.
The Start-up Mix and the Cook Mode Auto-Mix operations are
specialized versions of the Quick Filter, and share some of the
Quick Filter programmable parameters. For example, both of the
Mix operations use the Quick Filter's "Max Pump Time" setting.
FC-1 "QUICK FILTER: AFTER 'X' COOKS"
Controls automatic activation of the Quick Filter after the
specified number of cook cycles.
1.
Enter a new value by using the product numbers.
2.
Press the button next to √ to accept the new value.
3.
Press the button next to X to return to default or previous
setting.
46

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents