Henny Penny PXE-100 Operator's Manual page 56

Velocity series pressure fryer
Hide thumbs Also See for PXE-100:
Table of Contents

Advertisement

4-4.
FILTER CONTROL
(CONT.)
March 2014
FC-7 QUICK FILTER: FILL--NO DETECT: MAX
PUMP
The expected time it takes to refill the vat at the end of a Quick
Filter.
1.
Enter a new value by using the product numbers.
2.
Press the button next to √ to accept the new value.
3.
Press the button next to X to return to default or previous
setting.
FC-8 "QUICK FILTER: FILL: NO DETECT: MAX
PUMP"
If the fryer pumps for this amount of time during the Fill phase
without observing a temperature rise on the upper temperature
probe, the control turns the pump off, and asks "IS POT
FILLED?".
1.
Enter a new value by using the product numbers.
2.
Press the button next to √ to accept the new value.
3.
Press the button next to X to return to default or previous
setting.
For 50 Hz systems, or if the control routinely gives up before the
pot is refilled, you might need to increase the "max pump" time
from the default value. 50 Hz pumps may run more slowly than
60 Hz pumps.
Daily Filter Settings
FC-9 "DAILY FILTER: DROP OIL: TIME"
Controls the time duration of the initial draining of the pot.
1.
Enter a new value by using the product numbers.
2.
Press the button next to √ to accept the new value.
3.
Press the button next to X to return to default or previous
setting.
48