4-4.
FILTER CONTROL
(CONT.)
March 2014
Start-Up Mode Settings
FC-23 "START-UP: NEEDED IF TEMP < X"
If the oil temperature is below 215°F when the fryer is turned
on, the fryer always executes a Melt Mode -- regardless of this
"Start-up Needed" setting. Melt Mode is important in assuring
gentle heating of the oil when it is thick and perhaps not yet
flowing well.
1.
Enter a new value by using the product numbers.
2.
Press the button next to √ to accept the new value.
3.
Press the button next to X to return to default or previous
setting.
FC-24 "START-UP MIX: ENABLED?"
Phase 2 of the morning startup procedure is to execute the Start-
up Mix operation: drop all of the oil into the drain pan, filter it
for a short time, and pump it back into the vat. This feature is
important in thermally mixing the oil to eliminate cold spots and
eliminate the milky oil in the bottom of the pot.
This setting controls whether or not the Mix operation is
performed automatically as part of morning start-up. It is
recommended that the Start-up Mix feature is always enabled.
1.
Press the + or - to select either "YES" or "NO".
FC-25 "START-UP MIX: PRE-HEAT MAX TEMP"
The Start-Up Mix procedure consists of two steps:
Heat up the oil to the Mix Preheat temperature.
Drop the oil, filter, and refill the pot.
1.
Enter a new value by using the product numbers.
2.
Press the button next to √ to accept the new value.
3.
Press the button next to X to return to default or previous
setting.