DISPLAY
System data lost. Both the RAM
"E-41S"
copy and stored copy of the
"SYSTEM DATA
settings have been lost. Settings
LOST'
are reset to default
"E-46C"
"INTERNAL SD
Issue with microSD chip
MEM ERR"
Unable to communicate and save
"E-46W"
data to the microSD chip
"DATA SAVE
FAILED"
Corrupt file
"E-47"
Problem reading the A-to-D
"ANALOG
Analog to Digital converter
SYSTEM OR 12
inputs
VOLT FAILED"
"E-48"
"INPUT SYSTEM
Failure of the CPU board
ERROR"
"E-54C"
"MAIN TEMP
Fault on the CPU board
CIRCUIT
FAILURE"
"E-54D"
"MAIN TEMP DSC
Fault on the CPU board
ERROR"
"E-70A"
Jumper wire is loose or missing
"FAN JUMP
from 15 pin connector
MISSING"
Nov 2016
CAUSE
64
CORRECTION
Replace control board if occures
repeatedly
Check to ensure chip is not ejected from
slot
Replace control board if occures
repeatedly
Initialize the CPU board
Replace control board
Replace control board
Initialize the CPU board
Replace control board
Initialize the CPU board
Replace control board
Check connector for loose connection