4-4.
FILTER CONTROL
(CONT.)
March 2014
FC-20 "AUTO-TOPOFF: REPEAT"
Specifies how long the control waits before assessing the oil
level and generating a second ATO pulse if the oil level is still
low.
1.
Enter a new value by using the product numbers.
2.
Press the button next to √ to accept the new value.
3.
Press the button next to X to return to default or previous
setting.
FC-21 "AUTO-TOPOFF: AFTER X ATTEMPTS,
CHECK ATO"
After each ATO pulse, the control monitors the level probe
temperature to see if the oil has been brought up to the proper
level. If not, a second ATO pulse is given. After a certain number
of pulses, as specified by this setting, if the oil level still has
not been brought up to the proper level, the control beeps and
displays "FILL OIL TANK".
1.
Enter a new value by using the product numbers.
2.
Press the button next to √ to accept the new value.
3.
Press the button next to X to return to default or previous
setting.
If "X" pulses of oil haven't brought the level up, the control
assumes that the oil tank is empty -- that no oil is being pumped
into the pot -- and displays the "Fill Oil Tank" message.
If the fryer is configured to use a Bulk Oil Supply system, the
message displayed is "CHECK BULK OIL SUPPLY" rather
than "FILL OIL TANK". In this case, it is possible that the
remote bulk supply tank is empty, that the bulk supply plumbing
connection is not connected to the fryer, or that the bulk supply
electrical connection is not connected.
FC-22 "COOK MODE - FORCED ATO CHECK
AFTER 'X' COOKS"
1.
Enter a new value by using the product numbers.
2.
Press the button next to √ to accept the new value.
3.
Press the button next to X to return to default or previous
setting.
52