2-10.
ELECTRICAL
REQUIREMENTS
July 2003
The gas fryer requires 120 volt, single phase 60 Hertz, 10 amp,
3 wire grounded (earthed) service, or 230 volt, single phase, 50
Hertz service. The 120 volt gas fryer is factory equipped with
a grounded (earthed) cord and plug for your protection against
shock, and should be plugged into a 3 prong grounded (earthed)
receptacle. Do not cut or remove grounding (earthing) prong.
A wiring diagram is located behind the right side panel, and can
be accessed by removing the side panel. The 230 volt plug must
conform to all local, state, and national codes.
To avoid electrical shock, do not disconnect the
ground (earth) plug. This fryer must be adequately
and safely grounded (earthed). Refer to local
electrical codes for correct grounding (earthing)
procedures or in absence of local codes, with The
National Electrical Code, ANSI/NFPA No. 70-
(the current edition). In Canada, all electrical
connections are to be made in accordance with CSA
C22.1, Canadian Electrical Code Part 1, and/or
To avoid electrical shock, this appliance must be
equipped with an external circuit breaker which will
disconnect all ungrounded (unearthed) conductors.
The main power switch on this appliance does not
disconnect all line conductors.
13
local codes.