Henny Penny PXE-100 Operator's Manual page 71

Velocity series pressure fryer
Hide thumbs Also See for PXE-100:
Table of Contents

Advertisement

DISPLAY
"E-14"
Pressure is too high within the
"PRESSURE TOO
frypot
HIGH"
The control energized the drain
valve to close it, and waited a
"E-15C"
reasonable amount of time, but
"DRAIN VALVE
didn't see the expected feedback
ERROR"
signal that would have confirmed
that the drain valve was fully
closed.
The control energized the drain
valve to open it, and waited a
"E-15P"
reasonable amount of time, but
"DRAIN VALVE
didn't see the expected feedback.
ERROR"
signal that would have confirmed
that the drain valve was fully
open.
"E-18A"
"LEVEL SENSOR
FAILED"
(Open Circuit)
The oil level probe has failed
"E-18B"
"LEVEL SENSOR
FAILED"
(Shorted)
System data lost. Both the RAM
"E-41P"
copy and stored copy of the
"-1- LOST"
settings have been lost. Settings
are reset to default
Nov 2016
CAUSE
Check the drain valve for obstruction.
Carefully remove any obstruction found.
If no obstruction, check to make sure both
connections to the drain valve are plugged in
securely. If connections are secure, operate
the drain valve using the drain valve test in
tech mode. If no drain valve movement,
test to make sure the drain valve is getting
24VDC from control board when testing both
directions (open and closed) from connector
P9 pins 3&4. If voltage is present and no
movement, replace drain valve motor. If no
DC voltage, replace control board
Check to make sure both connections to
the drain valve are plugged in securely. If
connections are secure, operate the drain
valve using the drain valve test in tech mode.
If no drain valve movement, test to make sure
the drain valve is getting 24VDC from control
board when testing both directions (open
and closed) from connector P9 pins 3&4. If
voltage is present and no movement, replace
drain valve motor. If no DC voltage, replace
control board
63
CORRECTION
Check deadweight chamber for any
obstruction
Check the steam exhaust passage for
obstruction
If circuit is open, check connection
Replace probe
Replace control board if occures
repeatedly