4-4.
FILTER CONTROL
(CONT.)
March 2014
FC-30 "START-UP ATO CHECK: ENABLED?"
Specifies whether or not the ATO (auto-topoff) Check -- the third
step of the Start-up Mode -- is enabled.
1.
Press the + or - to select either "YES" or "NO".
FC-31 "START-UP ATO CHECK: PRE-HEAT MAX
TEMP"
The Start-Up Auto-Polish procedure consists of two steps:
Heat up the oil to the Polish Preheat temperature.
Drop the oil, filter (for a long time), and refill the pot.
1.
Enter a new value by using the product numbers.
2.
Press the button next to √ to accept the new value.
3.
Press the button next to X to return to default or previous
setting.
FC-32 "START-UP POLISH: ENABLED?"
Phase 4 of the morning startup procedure is to execute the Start-
up Auto-Polish: drop the oil into the drain pan, filter it for a long
time, and pump it back into the pot. This feature is important in
cleaning the oil and restoring clarity to it. Filter powder should
be added to the drain pan in order for the Polish operation to be
most effective.
1.
Press the + or - to select either "YES" or "NO".
FC-33 "START-UP POLISH: PRE-HEAT MAX
TEMP"
The Start-Up Auto-Polish procedure consists of two steps:
Heat up the oil to the Polish Preheat temperature.
Drop the oil, filter (for a long time), and refill the pot.
1.
Enter a new value by using the product numbers.
2.
Press the button next to √ to accept the new value.
3.
Press the button next to X to return to default or previous
setting.
55