Henny Penny PXE-100 Operator's Manual page 59

Velocity series pressure fryer
Hide thumbs Also See for PXE-100:
Table of Contents

Advertisement

4-4.
FILTER CONTROL
(CONT.)
March 2014
FC-17 "POLISH: FILL: NO DETECT: MAX PUMP"
If the fryer pumps for this amount of time during the Fill phase
without observing a temperature rise on the upper temperature
probe, the control turns the pump off, and asks "IS POT
FILLED?". If pot is not filled completely, press "NO" and the
pump will attempt to fill further.
1.
Enter a new value by using the product numbers.
2.
Press the button next to √ to accept the new value.
3.
Press the button next to X to return to default or previous
setting.
For 50 Hz systems, or if the control routinely gives up before the
pot is refilled, you might need to increase the "max pump" time
from the default value. 50 Hz pumps run more slowly than 60 Hz
pumps.
Auto-Top Off Settings
FC-18 "AUTO-TOPOFF: ENABLED?"
Enables or disables all Auto-Topoff (ATO) operations.
1.
Press the + or - to select either "YES" or "NO".
Disabling the Auto-Topoff feature would normally be done only
if the topoff system itself has failed, in order to avoid the "Fill
Oil Tank" messages that occur if the fryer doesn't detect oil at
the proper level after 3 attempts.
FC-19 "AUTO-TOPOFF: PUMP TIME"
Specifies how long the ATO pump runs for each individual ATO
pulse.
1.
Enter a new value by using the product numbers.
2.
Press the button next to √ to accept the new value.
3.
Press the button next to X to return to default or previous
setting.
This setting may be manually adjusted as needed. Ideally, each
ATO pulse pumps about 1/8" to 3/16" (5 mm) of fresh oil into
the pot.
51