Henny Penny PXE-100 Operator's Manual page 70

Velocity series pressure fryer
Hide thumbs Also See for PXE-100:
Table of Contents

Advertisement

DISPLAY
High limit tripped while
"E-10F"
filtering (including AutoFilter,
"HIGH LIMIT
Daily Filter, Polish, Dispose,
TRIPPED"
Drain to Pan, Fill from Pan, etc.).
"E-10M"
High limit tripped while fryer
"HIGH LIMIT
was in Melt Mode.
TRIPPED"
High limit tripped while vat
"E-10S"
was in Start-up Mode (not incl.
"HIGH LIMIT
Melt mode), but not while it was
TRIPPED"
executing one of the filter
operations.
High limit tripped less than 5
"E-10Y"
minutes after user responded
"HIGH LIMIT
"YES" to an "Is Pot Filled?"
TRIPPED"
question.
"E-13"
Pressure transducer failed
Nov 2016
CAUSE
Check the error log to find out the fry pot
temperature at the time the high limit tripped.
If this was several degrees above the oil set
point temperature, test for a sticking contactor
and replace if faulty. If the trip temperature
was near the oil set point temperature, inspect
the high limit thermocouples for carbon build
up and clean if necessary. If no carbon found,
see high limit troubleshooting.
Check the error log to find out the fry pot
temperature at the time the high limit tripped.
If this temperature was very low, this could
be a sign that the fry pot was turned on with
low or no oil. If this was the case, fill the pot
with oil and reset the high limit. If the high
limit tripped at a higher temperature, inspect
the high limit thermocouples for carbon build
up and clean if necessary. If no carbon found,
see high limit troubleshooting.
Check the error log to find out the fry pot
temperature at the time the high limit tripped.
If this temperature was very low, this could
be a sign that the fry pot was turned on with
low or no oil. If this was the case, fill the pot
with oil and reset the high limit. If the high
limit tripped at a higher temperature, inspect
the high limit thermocouples for carbon build
up and clean if necessary. If no carbon found,
see high limit troubleshooting.
Check the error log to find out the fry pot
temperature at the time the high limit tripped.
If this temperature was very low, this could
be a sign that the fry pot was turned on with
low or no oil. If this was the case, fill the pot
with oil and reset the high limit. If the high
limit tripped at a higher temperature, inspect
the high limit thermocouples for carbon build
up and clean if necessary. If no carbon found,
see high limit troubleshooting.
62
CORRECTION
Replace pressure transducer

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents