Figure A–3 Module LED States
Card LEDs
State
No LEDs lit
Testing in
progress
(flashing)
Loading
(flicker)
READY
FAULT
ATTENTION
HOTSWAP
Description
Card is disabled. Possible causes:
– No power to unit
– Card is waiting to run module self-test
(memory card only)
– Card is not installed correctly
– Fault on card or in slot
Module self-test is running on the card
(1 flash per second).
NIC is either waiting to load or loading the
software.
The card has passed its module self-test.
The module self-test has failed. Possible
causes:
– Fault on card
– Cabling problem
– Fault on DECNIS 600 unit
The NIC is running, but not all ports on
the card are usable. Possible causes:
– Fault on NIC
– Cabling problem
– Fault on DECNIS 600 unit
The NIC switch is down (NIC disabled)
and the NIC can be removed from the
system.