Introduction
Table 1–2 lists the three push-button switches and describes their functions.
Table 1–2 LSB Control Panel Push-button Switches
Switch
Position
On/Off
Out
In
Secure
Out
In
Restart
Out
(Momentary
switch)
In
The LSB control panel also includes three status LED indicators. Table 1–3 lists
these LEDs and describes their functions.
Table 1–3 LSB Control Panel Status LED Indicators
LED Name/Color
Function
Power
Lit when the 48 Vdc power supply is on and the output is within
(Green)
specifications.
If not lit after the On/Off switch is depressed, the power supply has
detected an overvoltage or overcurrent condition.
Run
Lit when console mode is terminated and system program execution
(Green)
begins.
Not lit during power sequencing and when in console mode.
Fault
Blinks at a slow 2-second rate during the power-up sequence and
(Amber)
at a fast .5-second rate during the power-down sequence. After the
power-up sequence, it stays lit until all LSB and I/O modules have
passed self-test, and then goes out.
Being lit during normal operation indicates a blower failure, an
LSB or I/O module not passing self-test, or a power supply fault.
1–6 Introduction
LED Status
/Color
Description
Off
The 48 Vdc power supply is turned off.
On (Green)
The 48 Vdc power supply is turned on and
48 Vdc is present.
Off
Indicates to the console firmware that
certain privileged console commands are
allowed.
On (Green)
Indicates to the console firmware that
certain privileged console commands are not
allowed.
Off
The system restart signal is not being
asserted.
On (Red)
The system restart signal is being asserted.