Page 1
DEC 3000 Model 400S/600S/700S AXP Rackmount Server Installation/Owner’s Guide Order Number: EK–RSNDP–IN. C01 Revision/Update Information: This is a revised document. Digital Equipment Corporation Maynard, Massachusetts...
Page 2
The postpaid Reader’s Comments forms at the end of this document request your critical evaluation to assist in preparing future documentation. The following are trademarks of Digital Equipment Corporation: AXP, DEC, DECchip, DECUS, DECstor/me, OpenVMS, PDP, TURBOchannel, ULTRIX, VAX, VMS, and the DIGITAL logo.
DEC 3000 Model 400/400S AXP Options Guide • DEC 3000 Model 600/600S/700 AXP Options Guide This guide provides information for installing the DEC 3000 Model 400S/600S/700S AXP Rackmount Server. Also covered are items unique to the rackmount server, and the removal and installation instructions for failed or damaged Field Replaceable Units (FRUs).
(RETMA) rack or cabinet. Additional information concerning installing, turning on, and maintaining the system are covered in Part I of the DEC 3000 Model 400/400S Owner’s Guide or DEC 3000 Model 600/600S/700 Owner’s Guide as applicable. Installation in a rack should be performed by trained service personnel.
Page 11
Lower case letters in this format indicate a show config command that must be entered as shown. For example: the command. show config rackmount This term refers to the DEC 3000 Model server 400S/600S/700S AXP Rackmount Server system.
Page 12
Important Safety Notes The following symbols appear on the power supply. Please review their definitions below: This Dangerous Voltage warning symbol indicates risk of electric shock and indicates hazards from dangerous voltage. This Attention symbol is used to alert readers about specific safety conditions, and to instruct the reader to read separate instructional material.
This part also describes how to verify an installation site and install the system. Detailed information on performing basic operations is contained in Part I of the DEC 3000 Model 400/400S AXP Owner’s Guide or DEC 3000 Model 600/600S/700 AXP Owner’s Guide and will be referred to as applicable.
Chapter Overview Introduction The DEC 3000 Model 400S/600S/700S AXP Rackmount Server (see Figure 1–1) is the rackmount version of the DEC 3000 Model 400S/600S/700S AXP Server described in the DEC 3000 Model 400/400S AXP Owner’s Guide or DEC 3000 Model 600/600S/700 AXP Owner’s Guide.
Chapter Overview Refer to Chapter 1 in the DEC 3000 Model 400/400S AXP Owner’s Guide or DEC 3000 Model 600/600S/700 AXP Owner’s Guide as applicable for information about: • System features • Software product descriptions • Operating systems • Audio capabilities •...
In This Chapter This chapter covers the following topics: • Verifying the Site Preparation • Unpacking the Rackmount Server System • Location of Controls and Indicators Preparing to Install the DEC 3000 Model 400S/600S/700S AXP Rackmount Server 2–1...
Preparation Guide (EK-CSEPG-MA) (not shipped with the system). • The system is located in an area that provides sufficient clearance for ventilation and servicing. Figure 2–1 shows the clearance required around the system. 2–2 Preparing to Install the DEC 3000 Model 400S/600S/700S AXP Rackmount Server...
Page 19
The system weighs 34 kg (75 lbs). To prevent personal injury and equipment damage, ensure that the system is contained in an enclosure that can be stabilized when the system is pulled out on its slides. Preparing to Install the DEC 3000 Model 400S/600S/700S AXP Rackmount Server 2–3...
(19 in) 61 cm (24 in) 61 cm 61 cm (24 in) (24 in) 68.6 cm (27 in) 61 cm (24 in) MK428-31 Cabinet or rack Rackmount server 2–4 Preparing to Install the DEC 3000 Model 400S/600S/700S AXP Rackmount Server...
The DEC 3000 Model 400S/600S/700S AXP Rackmount Server weighs 34 kg (75 lbs). Digital recommends that at least two people remove it from the shipping box, as indicated on the packing carton. Preparing to Install the DEC 3000 Model 400S/600S/700S AXP Rackmount Server 2–5...
flat blade) Owner’s guides, Printer port terminator options guide, 10BASE-T terminator other documentation Modem loopback connector System power cord Pair of slides SCSI terminator Cable carrier 2–6 Preparing to Install the DEC 3000 Model 400S/600S/700S AXP Rackmount Server...
Unpacking the Rackmount Server System Figure 2–2 Rackmount Server Components and Parts MK428-40 Preparing to Install the DEC 3000 Model 400S/600S/700S AXP Rackmount Server 2–7...
Table 2–2 lists the mounting hardware included with the system Hardware for installation into a RETMA standard 19-inch rack. Table 2–2 Mounting Hardware Description Part Number Quantity Slide assembly 12-32764-05 1 pair Cable carrier 12-26281-01 2–8 Preparing to Install the DEC 3000 Model 400S/600S/700S AXP Rackmount Server...
Guide or DEC 3000 Model 600/600S/700 AXP Owner’s Guide. Figure 2–3 shows the location of the ports, switches and indicators at the rear of the rackmount server system; Table 2–3 describes their functions. Preparing to Install the DEC 3000 Model 400S/600S/700S AXP Rackmount Server 2–9...
A Closer Look at the Rackmount Server System Figure 2–3 Rear View of Rackmount Server System MK428-17 2–10 Preparing to Install the DEC 3000 Model 400S/600S/700S AXP Rackmount Server...
To turn the system unit power ON | and OFF (O) Power On/Off When lit, indicates that the rackmount server is on indicator Not supported in the DEC 3000 Model 400S/600S/700S AXP Rackmount Server Preparing to Install the DEC 3000 Model 400S/600S/700S AXP Rackmount Server 2–11...
Front of the Figure 2–4 shows the front of the system. Table 2–4 describes Rackmount the items shown. Server System Figure 2–4 Front View of the Rackmount Server System MK428-13 2–12 Preparing to Install the DEC 3000 Model 400S/600S/700S AXP Rackmount Server...
Optional Slot for inserting: an RRD43 compact removable disc drive, an RX26 floppy disk drive, media device a TLZ06 drive, a TKZ10 drive, or a slot TZ30 drive. Preparing to Install the DEC 3000 Model 400S/600S/700S AXP Rackmount Server 2–13...
Installing the Rackmount Server Introduction This chapter, along with the information contained in Chapter 4 of the DEC 3000 Model 400/400S AXP Owner’s Guide or the DEC 3000 Model 600/600S/700 AXP Owner’s Guide as applicable, provides the information to install the DEC 3000 Model 400S/600S/700S AXP Rackmount Server in a 19-inch RETMA rack.
Installing the System on Slides Installing the System on Slides The rackmount server is shipped with one pair of slide assemblies (P/N 12-32764-05), which include: • Two rear brackets. • Two front brackets. • Pair of slide assemblies. • Attaching hardware. Installing the system on slides, involves: 1.
Installing the System on Slides 3. Orient the slide so that the arrow next to the locking lever is pointing upward. 4. Slide the long bracket (rear bracket) on the rear of the slide assembly in the direction of the arrow. Figure 3–1 Attaching Brackets to Slide Assembly MK428-42 5.
Installing the System on Slides 8. To fasten the front bracket to the slide assembly, proceed as follows: a. Pull out the inside slide about half way, enough to align two half-inch access holes on the inside slide with the mounting holes on the slide assembly and the front bracket...
Installing the System on Slides system. Otherwise, the slide will be damaged when the system is installed on the slides. 2. Attach the right slide race to the right side of the system chassis using four pan head screws 3. Remove the race from the slide assembly labeled LH. 4.
Installing the System on Slides Locating the Before attaching the slides to the rack, you must first identify Rail Mounting the system location in the rack and establish a datum line. The Holes datum line serves as a reference to identify the mounting hole positions for the slide bracket, U-nuts and cable management bracket.
Installing the System on Slides Attaching the To attach the slides to the rails, refer to Figure 3–4 and proceed Slides to Rails as follows: 1. Locate the slide assembly labeled RH. Attach the RH slide assembly to the right front rail (when facing front of rack) using two 10-32 screws and nut bar...
Installing the System on Slides Mounting the To mount the chassis on the slides, refer to Figure 3–5 and Chassis on proceed as follows: Equipment Slides Warning Use sufficient personnel and proper equipment when lifting or moving the rackmount server system.
Installing the System on Slides Installing the To install the cable carrier, refer to Figure 3–6, and proceed as Cable Carrier follows: 1. Push the system into the rack. 2. Using the top rear edge of the system chassis as a reference point, count downward to locate the first and fourth mounting holes on the left-rear rail (facing the rear of the...
Connecting the Rackmount Server Instructions for connecting the system are contained in Chapter 4 and Chapter 5 of the DEC 3000 Model 400/400S AXP Owner’s Guide or DEC 3000 Model 600/600S/700 AXP Owner’s Guide as applicable. In Chapter 4 follow these instructions: 1.
Tying Off Cables to Cable Carrier Arm After performing the procedure described in Alternate Console Switch Setting (Chapter 4 of the DEC 3000 Model 400/400S AXP Owner’s Guide or DEC 3000 Model 600/600S/700 AXP Owner’s Guide as applicable), dress the system power cable and data cables along the cable carrier arm using tie wraps and holes provided in the arm.
400S/600S/700S AXP Rackmount Server. A complete description of these features and other advance operations are provided in Part II of the DEC 3000 Model 400/400S AXP Owner’s Guide or the DEC 3000 Model 600/600S/700 AXP Owner’s Guide as applicable, which includes information about the following: •...
Where to Go The password security feature is the same as that described in Chapter 11 of the DEC 3000 Model 400/400S AXP Owner’s Guide or the DEC 3000 Model 600/600S/700 AXP Owner’s Guide. However, accessing the secure system jumper is different for the rackmount server.
Where to Go Figure 4–1 Location of Security System Jumper MK428-14 I/O board Secure system jumper (ON Secure system jumper position) (OFF position) 4–2 Using the Password Security Feature...
Part III Resolving Problems For information concerning resolving problems, refer to Part III in the DEC 3000 Model 400/400S AXP Owner’s Guide or the DEC 3000 Model 600/600S/700 AXP Owner’s Guide as applicable, which includes information about the following: •...
Page 51
Option Removal and Installation Procedures Part IV provides the module/subassembly removal and installation procedures for the DEC 3000 Model 400S/600S/700S AXP Rackmount Server. Because the rackmount server has a different chassis for rack mounting, the procedures differ from the desktop products and should be performed by trained service personnel.
Whenever performing any removal or installation procedure, ensure that the ac power On/Off switch located at the rear of the DEC 3000 Model 400S/600S/700S AXP Rackmount Server is in the OFF position and the power cord is disconnected from the ac power source.
In This Chapter In This Chapter This chapter describes how to prepare the system for service and how to remove and install the following items: • Top cover • Front bezel • Removable-media devices • Fixed-media devices • TURBOchannel option •...
For information about , refer to Chapter 15, show config Running Diagnostic Tests, in the DEC 3000 Model 400/400S AXP Owner’s Guide or Chapter 13, Interpreting the Show Command Displays, in the DEC 3000 Model 600/600S/700 AXP Owner’s Guide as applicable.
Removing the Covers Removing the Covers Introduction Before servicing the system, the system must be pulled out of the rack on its slides and the top and front covers removed. In all cases the top cover is removed. Both top and front covers must be removed when removing or installing the fan or removable-media devices.
Removing the Covers Figure 5–1 Pulling Out the System MK428-02 Placing the To place the system back into the rack, refer to Figure 5–1 System Back proceed as follows: into the Rack 1. If the system was pulled out all the way, pull up on the slide locks before pushing the system back into the rack.
Removing the Covers Removing the Top Cover Warning Allow at least 5 minutes from the time the system unit power is turned OFF until you open the system unit. This gives the power supply capacitors time to discharge safely. To remove the top cover, refer to Figure 5–2 and proceed as follows: 1.
Removing the Covers Figure 5–2 Removing the Top Cover MK428-05 Removing the To remove the front cover, refer to Figure 5–3 and proceed as follows: Front Cover 1. Remove five screws fastening the front cover to the system chassis 2. Pull the front cover out away from the front of the system chassis and remove.
Removing the Covers Installing the To install the front cover, reverse all the steps in the removal Front Cover procedure for installation. Figure 5–3 Removing the Front Cover MK428-03 5–8 Removal and Installation Procedures...
Set the switches on the new drive according to these settings. To set the new drive differently, refer to the DEC 3000 Model 400/400S AXP Options Guide or the DEC 3000 Model 600/600S/700 AXP Options Guide as applicable for drive setup information.
Removable-Media Devices 6. Remove the four retaining screws fasting the media device to the drive bracket 7. Remove the media device from the drive bracket Figure 5–4 Removing Removable-Media Devices MK428-06 5–10 Removal and Installation Procedures...
Removable-Media Devices Installing Removable-Media Note Devices Refer to the label on the bracket (see Figure 5–4) for the correct mounting holes used in attaching the media device to the drive bracket. Caution When installing the drive bracket in the chassis, make sure the power cable and SCSI cable positioned so they are not pinched underneath the...
Set the switches on the new drive according to these settings. To set the new drive differently, refer to the DEC 3000 Model 400/400S AXP Options Guide or the DEC 3000 Model 600/600S/700 AXP Options Guide as applicable for drive setup information.
Fixed-Media Devices To install the fixed-media device, reverse the steps in the removal procedure. Figure 5–5 Removing Fixed-Media Devices MK428-07 Removal and Installation Procedures 5–13...
TURBOchannel option and set the switches or jumpers to the same value on the new option. For other setup information, refer to the DEC 3000 Model 400/400S AXP Options Guide or the DEC 3000 Model 600/600S/700 AXP Options Guide as applicable.
TURBOchannel Options 6. Lift the TURBOchannel option board off the standoffs connector on the I/O module. Figure 5–6 Removing TURBOchannel Options MK428-08 Installing TURBOchannel Caution Options Follow antistatic precautions anytime a module is replaced in the system. Refer to Antistatic Precautions for details.
SIMMs SIMMs Note If replacing one SIMM, make sure the replaceable SIMM is the same memory size and speed of the remaining seven SIMMs located on the same plane. Caution Follow antistatic precautions anytime a module is replaced in the system. Refer to Antistatic Precautions for details.
SIMMs Figure 5–7 Removing SIMMs/MMB MK428-09 Installing SIMMs/MMB Caution Follow antistatic precautions anytime a module is replaced in the system. Refer to Antistatic Precautions for details. To install SIMMs, reverse the steps in the removal procedure. Removal and Installation Procedures 5–17...
I/O Board I/O Board Note When replacing the I/O board, make sure the I/O shield is installed on the replacement module. Caution Follow antistatic precautions anytime a module is replaced in the system. Refer to Antistatic Precautions. Removing the To remove the I/O board, refer to Figure 5–8 and proceed as I/O Board follows: 1.
I/O Board 5. Locate the I/O board-to-system board connector on the underside of the I/O board (toward the front edge of the I/O board). 6. Apply equal upward pressure along the length of the I/O board-to-system board connector until it disconnects from the system board 7.
I/O Board Installing the If the I/O board is being replaced by a new board, refer to I/O Board Figure 5–9 and perform the following before installing the new I/O board: 1. Remove the Ethernet ROM Chip from the old I/O board and install it on the new I/O board 2.
For information on setting the variables, refer to the chapter, Changing Environment Variables, in the DEC 3000 Model 400/400S AXP Owner’s Guide or DEC 3000 Model 600/600S/700 AXP Owner’s Guide as applicable. Figure 5–9 Ethernet Chip and Jumper Locations MK428-45 Removal and Installation Procedures 5–21...
System Board System Board Note Record the position of the switches on the system board being replaced. When replacing the board, set switches on the new board in the same position. Caution Follow antistatic precautions anytime a module is replaced in the system. Refer to Antistatic Precautions for details.
System Board Figure 5–10 Removing the System Board MK428-16 Installing the System Board Caution Follow antistatic precautions anytime a module is replaced in the system. Refer to Antistatic Precautions for details. Carefully align the Halt switch and LEDs with the openings in the rear of the chassis to prevent damaging the switch.
Power Supply Power Supply Removing the To remove the power supply, refer to Figure 5–10 and proceed as Power Supply follows: 1. Remove the system board according to Removing the System Board, but do not remove the seven screws as instructed to release the system board from the metal shelf.
Power Supply To install the power supply, reverse the steps in the removal procedure. Figure 5–11 Removing the Power Supply MK428-12 Removal and Installation Procedures 5–25...
Removing the To remove the fan, refer to Figure 5–12 and proceed as follows: 1. Prepare the system for service according to Preparing for Service . 2. Remove the front bezel, top and front covers according to Removing the Covers . 3.
Hardware Specifications Appendix Overview Introduction Unless noted otherwise the hardware specifications in this appendix apply to DEC 3000 Model 400S, 600S, and 700S AXP rackmount server systems. In This This appendix covers the following topics: Appendix • System Dimensions •...
System Specifications System Specifications System Table A–1 provides the rackmount server system dimensions. Dimensions Table A–1 Rackmount Server Dimensions Weight Height Width Depth 34 kg 22.2 cm 48.2 cm 63.7 cm 75 lb 8.75 in 19 in 25.1 in Electrical Table A–2 provides information about the various electrical Specifications specifications for the rackmount server system.
Table A–3, Table A–4, and Table A–5 provide various information General Specifications about the DEC 3000 Model 400S, 600S, and 700S AXP systems and their components and options available at the time of print. Table A–3 System Specifications (DEC 3000 Model 400S)
System Specifications Table A–4 System Specifications (DEC 3000 Model 600S) Processor DECchip 21064 Alpha AXP microprocessor, with 8 KB data cache, 8 KB instruction cache and floating point unit, running at 175 MHz. Secondary cache 2 MB SIMM memory 32 MB minimum...
System Specifications Table A–5 System Specifications (DEC 3000 Model 700S) Processor DECchip 21064 A-225 Alpha AXP microprocessor, with 8 KB data cache, 8 KB instruction cache and floating point unit, running at 225 MHz. Secondary cache 2 MB SIMM memory...
System Specifications Environmental Table A–6 provides information about the environmental Limitations conditions in which the rackmount server can operate. Table A–6 System Environmental Specifications Operating/Storage Conditions Temperature range 5°C to 50°C (41°F to 122°F) Temperature change 11°C/hr (52°F/hr) maximum rate Relative humidity 10% to 95% (noncondensing) Maximum altitude...
DEC 3000 Model 400/400S/600/600S/700 AXP systems. The information explains the functions of pins on each port of the system unit. Refer to Appendix B of the DEC 3000 Model 400/400S AXP Where To Go Owner’s Guide or DEC 3000 Model 600/600S/700 AXP Owner’s Guide as applicable for pin-out information.
Associated Documents Appendix Overview Introduction This guide is used in conjunction with the DEC 3000 Model 400/400S AXP Owner’s Guide or DEC 3000 Model 600/600S/700 AXP Owner’s Guide, the DEC 3000 Model 400/400S AXP Options Guide or DEC 3000 Model 600/600S/700 AXP Options Guide, and other associated documents.
DEC 3000 Model 400/400S AXP Owner’s Guide EK-SNDPR-OG DEC 3000 Model 400/400S AXP Options Guide EK-SNDPR-OP DEC 3000 Model 400 AXP Setting Up Your Workstation EK-SNDPR-QC DEC 3000 Model 400 AXP Setting Up Your Server EK-SNDPV-QC DEC 3000 Model 400/400S AXP Service Guide...
54-21813 module, which is hosted within the rackmount server. Where To Go For this information refer to Appendix D in the DEC 3000 Model 400/400S AXP Owner’s Guide or the DEC 3000 Model 600/600S/700 AXP Owner’s Guide as applicable.
Recommended Spares List (RSL) Appendix Overview In This This appendix provides the recommended spares list (RSL) Appendix and also a list of other FRUs unique to the DEC 3000 Model 400S/600S/700S AXP Rackmount Server system. Recommended Spares List (RSL) E–1...
Page 94
Cable, disk power 70-30964-01 Cable, data 17-03801-01 Memory boards can be mixed. DEC 3000 Model 400S AXP DEC 3000 Model 600S AXP DEC 3000 Model 700S AXP DEC 3000 Model 600S AXP or 700S AXP E–2 Recommended Spares List (RSL)
Appendix Overview Table E–2 lists other FRUs used in the rackmount server Other Rackmount system. Server FRUs Table E–2 Other FRUs Fan Finger Guard 12-12561-00 Fingerstock, Top and Front 12-34888-09 Covers (cut-to-fit) Fingerstock, Removable Media 12-28686-15 (top/bottom) Fingerstock, Removable Media 12-28686-07 (sides) Shield, TURBOchannel...