A. The power switch on the DECNIS 600 is also a circuit breaker. If the
switch is set to 0 (OFF), set it to 1 (ON) to power up the system:
Power switch
(circuit breaker)
B. Refer to Section 9.2 for details of the LEDs and display codes shown on the
DECNIS 600.
C. If the DECNIS 600 immediately sets the circuit breaker switch to 0 (OFF)
again, there may be a problem with the power module. Complete the
following:
1. Replace the power module with a new power module (see Section 11.1).
2. Power up the DECNIS 600.
If the problem persists with the new power module, contact Digital
Services.