en | Appendices
Types
EN 50131
Class 1
Class 2
Class 3
Class 4
Class 5
Class 6
Tab. 8.8: Communicator types
8.4

Alarm reporting

ICP-MAP5000-COM has an integrated alarm reporting functionality.
It can be used for alarm transmission systems according to EN50136-2 SP4 or DP3. For DP3
compliant transmission, the alternate transmission path has to be wireless.
In case of a fault on the primary connection to a receiver, ICP-MAP5000-COM is connecting to
a backup receiver using the alternate transmission path.
The fault on the primary path is reported to the backup receiver and displayed on the control
center.
ICP-MAP5000-COM can report to any alarm receiver supporting the following protocols:
Transmission path faults are directly reported to the user via the MAP 5000 control center.
ICP-MAP5000-COM has implemented layer 1 supervision for Ethernet and wireless path.
ICP-MAP5000-COM supervises the link to Ethernet and polls the wireless network on checking
for connection, signal strength and sign in status.
The communicator in ICP-MAP5000-COM is realized as a pass-through system.
The monitoring center, to which the panel is connected to, has to provide proof of availability
of the alarm transmission system.
For information security purposes, ICP-MAP5000-COM provides the possibility of encrypted
transmission (AES 128, 192, 256).
To grant anti-substitution security, the initial key has to be provided manually by typing it into
the configuration software RPS for MAP.
2016.06 | 17 | F.01U.168.332
Demand-driven connection with 25-hourly (AÜA-B25) or 5-hourly function monitoring
(AÜA-B5)
Existing connection with 3-minute (AÜA-S180) or 20-second function monitoring (AÜA-
S20)
SES
AÜA-B25
AÜA-B5
AÜA-S180
AÜA-S20
Conettix IP
SIA DC 09
VDS 2465
Transmission procedure
Demand-driven connection with 25-hourly function
monitoring and voice annunciation
Demand-driven connection with 25-hourly function
monitoring and simple digital transmission
Demand-driven connection with 25-hourly function
monitoring and digital transmission
Demand-driven connection with 5-hourly function monitoring
and digital transmission
Existing connection with 180-second function monitoring and
digital transmission
Existing connection with 20-second function monitoring and
digital transmission
Installation manual
MAP 5000
Bosch Sicherheitssysteme GmbH