MAP 5000
8.3.5

Tamper surveillance of the main panel

Tamper switch with wall tamper
4
Location supervision of the panel
External alarm signaling by means of siren and/or remote alarm signaling with communicator
must be planned in accordance with Sirens and communicator in accordance with EN50131
grade 3, page 63.
1.
2.
Design types of the communicators according to SES
The transmission paths for remote alarm signaling are divided into the following:
Types
EN 50131
Class 1
Class 2
Class 3
Class 4
Class 5
Class 6
Tab. 8.7: Communicator types
8.4

Alarm reporting

ICP-MAP5000-COM and ICP-MAP5000-SC have an integrated alarm reporting functionality.
It can be used for alarm transmission systems according to EN50136-2 SP4 or DP3. For DP3
compliant transmission, the alternate transmission path has to be wireless.
Bosch Security Systems B.V.
When mounting the enclosure and installing the tamper switch, take the wall tamper of
the panel into account (refer to Mounting the enclosure, page 17 and Installing and
connecting the tamper switch, page 51).
In case of variants A, B and C with communicator(s) of classes 3 and 4, provide location
supervision for the panel as soon as one or more areas are armed.
It is possible to omit location supervision for variant D with class 5 communicator.
Realize the location supervision as a technical solution by the intrusion alarm system
itself. Therefore, ensure the EN-compliance of the requirements for disarming.
Or:
Realize the location supervision by security-relevant persons who guarantee that actions
that pose a risk to security are detected at all times at the time of the required location
supervision.
Demand-driven connection with 25-hourly (AÜA-B25) or 5-hourly function monitoring
(AÜA-B5)
Existing connection with 3-minute (AÜA-S180) or 20-second function monitoring (AÜA-
S20)
SES
AÜA-B25
AÜA-B5
AÜA-S180
AÜA-S20
Transmission procedure
Demand-driven connection with 25-hourly function
monitoring and voice annunciation
Demand-driven connection with 25-hourly function
monitoring and simple digital transmission
Demand-driven connection with 25-hourly function
monitoring and digital transmission
Demand-driven connection with 5-hourly function monitoring
and digital transmission
Existing connection with 180-second function monitoring and
digital transmission
Existing connection with 20-second function monitoring and
digital transmission