Advertisement

Chapter 7 Input Module Reference Data
1-Port and 3-Port E1 Input Modules
User can select high or low logic level as alarmed
If the hardware indicates that the cesium fault level matches the alarmed setting,
log an AIS alarm against port 1
Clear the alarm when the hardware's cesium fault level no longer matches the
alarmed level
Input Measurement Problems
If the MTIE values for a selected clock exceed either of the MTIE masks, the Input
module takes appropriate action according to the severity level associated with the
MTIE alarms.
If a received SSM has a lower PQL than the provisioned value assigned to the port
and the port has SSMs enabled, the Input module performs the action required by
the alarm mode.
E1 Input Module Events Reported
The E1 Input module reports the event types listed in
Table 7-2. E1 Input Module Event Reporting
Event
Module installed
Module enabled
Module disabled
Module restarted
Input Signal Episode,
Alarm, and Faults
Hardware Faults
Received SSM Changed
Phase Buildout
Configuration Changes
Input phase zeroed
166 SSU-2000 User's Guide
Parameter One
Delay before restart (in s)
New PQL
Phase value being built out
New Value (if necessary)
Table 7-2
when they occur:
Parameter Two
Old PQL
Corrected phase value
Old Value (if not implied by new value)
12713020-002-2 Revision F.01 – January 2007