Installing The Output Panels; Sample Rack Mounting With Input Module, Ssu-2000, And Output Panel - Symmetricom SSU-2000 User Manual

Synchronization supply unit and synchronization distribution unit
Hide thumbs Also See for SSU-2000:
Table of Contents

Advertisement

Chapter 8 Output Module Reference Data
E1 Line Re-timing Unit
3. Tighten the captive screws located at the top and bottom of the module front
panel.
Caution: To avoid possible damage or intermittent failure, ensure
that you have completely inserted the module into the system and
that you have securely tightened the captive screws. A partially
inserted module can easily become damaged and cause
intermittent failures.

Installing the Output Panels

The location of the output panels is limited only by the length of the interconnecting
cable. Output adapter cables are available in lengths from one to two meters in
increments of 0.1 meter; see the User Guide for part numbers. Use the following
steps to install the output panels.
1. The I/O adapter panels may be mounted flush to the top or bottom of the
SSU-2000 shelf, as shown in
Output Adapter panel to the rack.
2. Mount the panels to the front of the rack rails with four screws and washers.
2. Mount the panels to the front of the rack rails with four screws and washers.
Figure 8-32. Sample Rack Mounting with Input Module, SSU-2000, and Output Panel
262 SSU-2000 User's Guide
Figure
8-32. Use suitable screws for attaching the
12713020-002-2 Revision F.01 – January 2007