Troubleshooting; Sdu Corrective Action Table - Symmetricom SSU-2000 User Manual

Synchronization supply unit and synchronization distribution unit
Hide thumbs Also See for SSU-2000:
Table of Contents

Advertisement

Table 5-2. SDU Corrective Action Table
Component
Motherboard or Main Chassis
Fault
Defective Cable
Module Fault(s)
DS1 Output Module
E1 Output Module
CC Output Module
Japanese CC Output Module
Japanese Sine Wave Output
Module
E1/2048 kHz Output Module
2048 kHz Output Module
RS 422 Output Module
DS1 Dual Line Re-Timing Unit
DS1 Quad Line Re-Timing Unit
E1 Quad Line Re-Timing Unit

Troubleshooting

The SSU-2000 incorporates many alarms and event messages to alert that a
possible problem exists. These alarm and event message reports can be accessed
via the Communications module serial ports using a dumb terminal or PC.
Communication may also be established using the RJ-45 Ethernet connector
(ETHERNET 10-BASE-T) on the connector interface panel of the chassis.
Communicating by Serial
12713020-002-2 Revision F.01 – January 2007
Corrective Action
Contact Symmetricom Global
Services.
Replace defective cable.
a. Check that module(s) is seated
correctly.
b. Address any fault LED lights.
c. If present, press RST button on
Comms module.
d. Check both Power A and Power B
inputs for a tripped breaker or blown
fuse on the input power control panel.
e. Replace module.
f. If you are unable to correct the
problem, contact Symmetricom
Global Services.
Module Replacement
Port, on page 91, outlines the procedures for connecting
Chapter 5 Maintenance and Troubleshooting
Troubleshooting
Part Number
25413023-000-0
060-10003-10-2 (1 m
cable; other lengths
available)
All Modules
23413017-000-0
23413018-000-0
23413158-000-0
23413306-000-0
23413304-000-0
23413292-000-0
23413159-000-0
23413287-000-0
23413301-000-0
23413301-001-0
23413309-001-0
SSU-2000 User's Guide 131

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sdu-2000

Table of Contents