Symmetricom SSU-2000 User Manual page 179

Synchronization supply unit and synchronization distribution unit
Hide thumbs Also See for SSU-2000:
Table of Contents

Advertisement

Table 7-8. DS1 Input Module Configuration Settings (Continued)
Configuration Setting
MTIE T10 Set Limit2
MTIE T100 Set Limit1
MTIE T100 Set Limit 2
MTIE T1K Set Limit1
MTIE T1K Set Limit2
MTIE T10K Set Limit 1
MTIE T10K Set Limit 2
MTIE T100K Set Limit 1
MTIE T100K Set Limit 2
MTIE T10 Clear Limit1
MTIE T10 Clear Limit2
MTIE T100 Clear Limit1
MTIE T100 Clear Limit 2
MTIE T1K Clear Limit1
MTIE T1K Clear Limit2
MTIE T10K Clear Limit 1
MTIE T10K Clear Limit 2
MTIE T100K Clear Limit 1
MTIE T100K Clear Limit 2
MTIE Limit 1 Alarm Mode
MTIE Limit 2 Alarm Mode
Alarm Initial Severity
Alarm Initial Delay
Alarm Elevation Time
Port Status
Port Name
12713020-002-2 Revision F.01 – January 2007
Factory Default
325
440
550
810
1010
880
1100
1600
2000
230
290
400
490
730
910
790
990
1440
1800
Minor
Major
Minor (except LOS
and level 2 MTIE,
which are Major)
0 s
86 400 s
Disabled
None
Chapter 7 Input Module Reference Data
1-Port and 3-Port DS1 Input Modules
Range
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
Ignore | Report | Minor | Major | Critical
Ignore | Report | Minor | Major | Critical
Ignore | Report | Minor | Major | Critical
0 to 86 400 s
60 to 500 000 s, 0 is disabled
Enabled | Disabled
Any string from 0 to 20 characters
SSU-2000 User's Guide 179

Advertisement

Table of Contents
loading

Related Products for Symmetricom SSU-2000

This manual is also suitable for:

Sdu-2000