Chapter 8 Output Module Reference Data
2048 kHz Output Module
Table 8-15. Identifying Failed Ports from the Hex Digit
Hex Value
Digit 1
Digit 2
Digit 3
Digit 4
Digit 5
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Use the Alarm command to display the alarm information for a given module to
display all 2048 kHz Output module alarms, including Alarm #14, Squelching. Use
the Alarm command to provision these alarms to be Ignored or to generate a Report
Only, Minor Alarm, Major Alarm (default), or a Critical Alarm.
SSU+>al 2a10
2002-12-12T10:25:31 ID: SSU2000 Name: SSU
Output
#
------- ---- ------------------ --------------- ------------- ---------
2A10
(00) Redundant
2A10
(01) Module Match
2A10
(02) Clk-A
2A10
(03) Clk-B
2A10
(04) Clk-C
2A10
(05) Clk-D
2A10
(06) Clk Level
2A10
(07) Clk Selected
2A10
(08) VCXO
236 SSU-2000 User's Guide
Port
1
5
9
13
17
X
X
X
X
X
X
X
X
Alarm
Status
Ok
Ok
Ok
Ok
Ok
Ok
Ok
Ok
Ok
Port
Port
2
3
6
7
10
11
14
15
18
19
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Level(*=Elev) Ports
Major
Major
Major
Major
Major
Major
Major
Major
Major
12713020-002-2 Revision F.01 – January 2007
Port
4
8
12
16
20
X
X
X
X
X
X
X
X