Chapter 9 Hardware Configuration Guide
SSU-2000 Configuration Chart
Table 9-3. SSU-2000 System Components (Continued)
Item
Description
25.
2048 kHz Output
Module
26.
Composite Clock
Output Module
27.
E1/2048 kHz Output
Module
284 SSU-2000 User's Guide
Part Number
23413159-000-0
1. Minimum of one Output module of any
2. Each Output module provides 20 single
3. Each Output module or redundant pair
4. Each two redundant Output modules
23413158-000-0
1. Minimum of one Output module of any
2. Each Output module provides 20 single
3. Each output module or redundant pair
4. Each two redundant Output modules
23413292-000-0
1. Minimum of one Output module of any
2. Each Output module provides 20 single
3. Each Output module or redundant pair
4. Each two redundant Output modules
Notes
type required.
phase-locked 2048 kHz clock output
signals or 20 redundant phase-locked
2048 kHz clock output signals (if
desired) in even/odd slots.
requires one Output I/O adapter panel.
require one Output Summer connector
(part number 22013070-000-0).
type required.
byte and polarity phase aligned
independently configurable duty cycle
(50/50 or 62.5/37.5) and phase delay
from 0 to 3.4 msec CC output signals or
20 redundant (if desired) signals of the
same type in even/odd slots.
requires one Output I/O adapter panel.
require one Output Summer connector
(part number 22013070-000-0).
type required.
phase-locked E1 or 2048 kHz clock
output signals or 20 redundant phase-
locked E1 or 2048 kHz clock output
signals (if desired) in even/odd slots.
requires one Output I/O adapter panel.
require one Output Summer connector
(part number 22013070-000-0).
12713020-002-2 Revision F.01 – January 2007