Configuration Options; E1/2048 Khz Output Module - Symmetricom SSU-2000 User Manual

Synchronization supply unit and synchronization distribution unit
Hide thumbs Also See for SSU-2000:
Table of Contents

Advertisement

Table 8-10. Japanese Sine Wave Output Module Status LED Indicators (Continued)
Indicator
SOURCE C
Green/Amber
SOURCE D
Green/Amber
OUTPUT
Amber
FAULT

Configuration Options

Table 8-11
lists the Sine Output module configuration and default settings.
Table 8-11. Japanese Sine Wave Output Module Configuration Data
Setting
Frequency (Per Module)
Port Output (Per Port)
Bypass
Port Label (Per Port)
Alarm Elevation
Squelching (Per Port)

E1/2048 kHz Output Module

This section provides reference data for the E1/2048 kHz Output module (part
number 23413292-000-0) designed for use in the SSU-2000 Synchronization
Supply Unit.
12713020-002-2 Revision F.01 – January 2007
Color
On (Green) = The Bypass clock (Clock C) is the selected source
clock. See
Bypass Clock (Clock
On (Amber) = Faulty or missing source C clock
Off = Source C is ignored, or good and not selected
On (Green) = The Expansion clock (Clock D) is the selected
source clock. The module is in an Expansion shelf
On (Amber) = Faulty or missing source D clock
Off = Source D is good and not selected
On = Module has detected one or more faulty outputs
Off = All output signals are good
Default
6.312
Enable
Enable
Null
86 400 seconds
0
Chapter 8 Output Module Reference Data
E1/2048 kHz Output Module
Description
C), on page 30
Range
1.544 | 6.312
Enable | Disable
Enable | Disable
0 – 20 ASCII printable characters
60 – 500 000 seconds
0 is disabled
1 – 16
0 is disabled
SSU-2000 User's Guide 225

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sdu-2000

Table of Contents