Recommended Ssu-2000 Slots For Installing The Ds1 Lrm - Symmetricom SSU-2000 User Manual

Synchronization supply unit and synchronization distribution unit
Hide thumbs Also See for SSU-2000:
Table of Contents

Advertisement

Figure 8-24. Recommended SSU-2000 Slots for Installing the DS1 LRM
Installing the LRM in the SDU-2000
The SDU-2000 shelf has sixteen plug-in module slots. The slots are numbered A1
through A16, from left to right looking at the front of the shelf. When you install a
Line Re-timing Module into an SDU-2000, Symmetricom recommends that you use
only slots A5 through A12 as shown in
allows you to maintain redundant configuration options on other modules.
Note: Modules can be removed and inserted while system power is
supplied without damaging modules or affecting system operation.
Caution: For continued EMC compliance, replace all deformed
module gaskets with the same type. Clean gaskets and mating
surfaces. Secure all modules with captive screws.
12713020-002-2 Revision F.01 – January 2007
Chapter 8 Output Module Reference Data
DS1 Line Retiming Unit (LRU)
Figure
8-25. Using only the specified slots
SSU-2000 User's Guide 251