Symmetricom SSU-2000 User Manual page 100

Synchronization supply unit and synchronization distribution unit
Hide thumbs Also See for SSU-2000:
Table of Contents

Advertisement

CHpater 3 Provisioning and Operating the SSU-2000
Setting Security Parameters
Changing a User's Access Level
1. Type
USERS ACCESS
system prompts for the user name that is to receive the new access level.
2. Type the access level (1 through 4), then press Enter.
Deleting a User
1. Type
USERS DEL
system prompts for the user name that you want to delete.
2. Type the user name, then press Enter. The system deletes the user from the
user table.
Enabling, Disabling, and Unlocking Users
An Administrator-level user can enable or disable a user from accessing the
SSU-2000 without removing the user name from the user table. If a user exceeds
the number of failed attempts to log in, then the user name is locked for a period of
time. An Administrator-level user can unlock the user name and allow the user to
attempt to log in, overriding the Lockout Time parameter.
1. Type
USERS DISABLE
SSU-2000. The system prompts for the user name that you want to disable.
2. Type the user name, then press Enter. The system disables the user.
3. Type
USERS ENABLE
The system prompts for the user name that you want to enable.
4. Type the user name, then press Enter. The system enables the user.
5. Type
USERS UNLOCK
prompts for the user name that you want to unlock.
6. Type the user name, then press Enter. The system unlocks the user.
Using TL1 Commands
1. Connect a computer to port 2000 on the SSU-2000 and log in using an
Administrator-level user name and password, as described in
SSU-2000, on page 102.
2. Type
SET-PRMTR-SECU:::123::3,60,60;
attempts before disabling the user account, to set the lockout time to 1 minute,
and to set the password to expire in 60 days. The system responds with:
SSU_2000 06-02-21 20:27:35
A
000002 REPT EVT
"S1A02:NA,215,NSA,06-02-21,20-27-35:\"Security, Lockout, 60, TL1B\""
;
100 SSU-2000 User's Guide
then press Enter to change a user's access level. The
then press Enter to delete a user from the user table. The
then press Enter to disable a user from accessing the
then press Enter to allow a user to access the SSU-2000.
then press Enter to unlock a user name. The system
Logging In to the
to set to 3 the number of failed login
12713020-002-2 Revision F.01 – January 2007