Chapter 8 Output Module Reference Data
E1/2048 kHz Output Module
Table 8-12
lists the failed output port number(s) for each possible hex digit. In the
above alarm message, the hex number is 00001. To determine the port in alarm,
locate the second row (corresponding to Hex Value 1) in
column has an X, which corresponds to Port 20 (read across from Digit 5).
As another example, if the hex number is A501F, then the following ports are
squelched: 1 and 3 (corresponding to the A in Digit 1), 6 and 8 (corresponding to the
5 in Digit 2), 16 (corresponding to the 1 in Digit 4), and 17 through 20
(corresponding to the F in Digit 5).
Table 8-12. Identifying Failed Ports from the Hex Digit
Hex Value
Digit 1
Digit 2
Digit 3
Digit 4
Digit 5
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Use the Alarm command to display the alarm information for a given module; the
display includes all E1/2048 kHz Output module alarms, including Alarm #10,
Squelching. Use the ALARM command or the
(described in the SSU-2000 Technical Reference) to provision these alarms to
Ignore, Report Only, Minor Alarm, Major Alarm (default), or a Critical Alarm.
228 SSU-2000 User's Guide
Port
Port
1
2
5
6
9
10
13
14
17
18
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Table
8-12. The right-most
Port
3
7
11
15
19
X
X
X
X
X
X
X
X
SET-PRMTR-OUTE12048
12713020-002-2 Revision F.01 – January 2007
Port
4
8
12
16
20
X
X
X
X
X
X
X
X
command

Advertisement

Table of Contents
loading

Related Products for Symmetricom SSU-2000

This manual is also suitable for:

Sdu-2000

Table of Contents