Chapter 8 Output Module Reference Data
Japanese Composite Clock Output Module
Table 8-7. Japanese Composite Clock Output Module Status LED Indicators (Continued)
Indicator
SOURCE C
Green/Amber
SOURCE D
Green/Amber
OUTPUT
Amber
FAULT

Configuration Options

The configuration settings for the JCC Output module are listed in
Table 8-8. Japanese Composite Clock Output Module Configuration Settings
Configuration Setting
Port Output (Per Port)
Bypass
Operating Mode
JCC4 (400 Hz) Sync
Port Delay
Port Label (Per Port)
Alarm Elevation
218 SSU-2000 User's Guide
Color
On (Green) = The Bypass clock (Clock C) is the selected source
clock. See
Bypass Clock (Clock
On (Amber) = Faulty or missing Bypass clock
Off = Bypass clock is ignored, or good and not selected
On (Green) = The Expansion clock (Clock D) is the selected
source clock. The module is in an Expansion shelf
On (Amber) = Faulty or missing Expansion clock
Off = Expansion clock is ignored, or good and not selected
On = Module has detected one or more faulty outputs
Off = All output signals are good
Factory Default
Enable
Enable
Normal (SSU)
Enable
3 (1375 feet) in Normal
mode, 7 (275 feet) in
Subtending mode
Null
86 400 seconds
Description
C), on page 30
Table
Range
Enable | Disable
Enable | Disable
Normal | Japanese | Subtending
Enable | Disable
0 to 7
(2200, 1925, 1650, 1375, 1100,
825, 550, and 275 feet)
0 – 20 ASCII printable characters.
60 – 500 000 seconds
0 is disabled
12713020-002-2 Revision F.01 – January 2007
8-8.