Table 7-4. E1 Input Module Configuration Settings (Continued)
Configuration Setting
MTIE T10 Set Limit1
MTIE T10 Set Limit2
MTIE T100 Set Limit1
MTIE T100 Set Limit 2
MTIE T1K Set Limit1
MTIE T1K Set Limit2
MTIE T10K Set Limit 1
MTIE T10K Set Limit 2
MTIE T100K Set Limit 1
MTIE T100K Set Limit 2
MTIE T10 Clear Limit1
MTIE T10 Clear Limit2
MTIE T100 Clear Limit1
MTIE T100 Clear Limit 2
MTIE T1K Clear Limit1
MTIE T1K Clear Limit2
MTIE T10K Clear Limit 1
MTIE T10K Clear Limit 2
MTIE T100K Clear Limit 1
MTIE T100K Clear Limit 2
MTIE Limit 1 Alarm Mode
MTIE Limit 2 Alarm Mode
Alarm Initial Severity
Alarm Initial Delay
Alarm Elevation Time
Port Status
Port Name
12713020-002-2 Revision F.01 – January 2007
Factory Default
80
100
800
1000
1600
2000
2270
2835
4260
5330
70
90
700
900
1400
1800
2000
2500
3800
4800
Minor
Major
Minor (except LOS
and level 2 MTIE,
which are Major)
0 s
86 400 s
Disabled
None
Chapter 7 Input Module Reference Data
1-Port and 3-Port E1 Input Modules
Range
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
Ignore | Report | Minor | Major | Critical
Ignore | Report | Minor | Major | Critical
Ignore | Report | Minor | Major | Critical
0 to 86 400 s
60 to 500 000 s, 0 is disabled
Enabled | Disabled
Any string from 0 to 20 characters