Logging Off of the SSU-2000

Use one of the following commands to log off of the SSU-2000:
Using ICS commands
Type
and press Enter.
bye
Using TL1 commands
CANC-USER:::123;

Initial Provisioning

After you have established communications with the SSU-2000, you must provision
the unit so it can track the input signals and start generating outputs. This sections
contains general instructions for initial provisioning of the SSU-2000, and are not
intended to cover all combinations of Input and Output modules. You may need to
alter the commands in this section to match the configuration of your SSU-2000.

Provisioning General Parameters

This section describes how to provision the reference mode and the auto-return
mode, set the IP address, and name the unit.
1. Log in to the SSU-2000 using the procedure in
page 102.
2. Provision the reference selection mode. The default is Priority, which is the most
widely used mode. See
selecting the appropriate mode.
ICS command:
Type
REF PRI
TL1 command:
Type
SET-INPUT-REF:::123::port,PRI;
where 123 is an arbitrary ctag value and
format S1Ax[-z], where x is the slot number (3–12) and z is the port (1–3).
Repeat this command for all inputs.
3. Provision the clocks to enable auto-return (revertive) mode. Symmetricom
generally recommends that auto-return be set to On, unless both clocks are of
the same Stratum level. See
for more information on revertive and non-revertive modes.
ICS command:
Type
CLK AR ON
12713020-002-2 Revision F.01 – January 2007
Selecting the
, then press Enter.
Setting the Reference Switching
, then press Enter.
Chapter 3 Provisioning and Operating the SSU-2000
Logging In to the
Input, on page 28, for information on
is the selected input port in the
port
Initial Provisioning
SSU-2000, on
Mode, on page 29,