Configuration Options; Gps Input Module Configuration Settings - Symmetricom SSU-2000 User Manual

Synchronization supply unit and synchronization distribution unit
Hide thumbs Also See for SSU-2000:
Table of Contents

Advertisement

Configuration Options

The configuration settings for the GPS Input module are listed in
Table 7-10. GPS Input Module Configuration Settings
Configuration Setting
Position (GPS only)
Latitude
Longitude
Altitude
Averages
PDOP
Pos Mode
Min Elevation for position
Min PDOP for position
Min Elevation for timing
Module Status
Priority
Sigma limit
PQL
Disabled SV list
Min PDOP for position
FREQ Set Clk A
FREQ Set Clk B
FREQ Clear Clk A
FREQ Clear Clk B
Frequency Alarm Mode
MTIE T10 Set Limit1
MTIE T10 Set Limit2
MTIE T100 Set Limit1
MTIE T100 Set Limit 2
MTIE T1K Set Limit1
MTIE T1K Set Limit2
MTIE T10K Set Limit 1
MTIE T10K Set Limit 2
12713020-002-2 Revision F.01 – January 2007
Factory Default
0
0
0
300
0
Calc
5
3
10
Enabled
0
25
2
None
3
16 000
16 000
12 000
12 000
Major
260
325
440
550
810
1010
880
1100
Chapter 7 Input Module Reference Data
Range
± 90 degrees
±180 degrees
–60 to 4000 meters
10 to 3600
1 to 10
User | Calc
0 to 50 degrees
1 to 10
0 to 50 degrees
Enabled | Disabled
0 to 10
10 to 1000 μs
1 to 16
Up to 31 SV numbers
1 to 10
0 to 10 000 000
0 to 10 000 000
0 to 10 000 000
0 to 10 000 000
Ignore | Report | Minor | Major | Critical
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
SSU-2000 User's Guide 183
GPS Input Module
Table
7-10.