Provisioning Other Input Modules

This section describes how to enable and provision other types of Input modules
such as DS1, E1, or Composite Clock. You must enable and provision each input
port as appropriate for the input signal. You can install these Input modules in any
slot in the main SSU-2000 shelf.
1. Log into the SSU-2000 using the procedure in
page 102.
2. Enable the modules:
ICS command:
Type
INPUT xAy-z ENABLE
where x is the shelf number, y is the slot number, and z is the port number.
Repeat this command for each port and each slot.
TL1 command:
See the command in step 3, below.
3. Set the priority level for each port. Set the input Priority to a value from 0 to 10; 0
indicates that the port is Monitor-only and is never selected as a reference signal.
1 is highest priority, and 10 is lowest.
ICS command:
Type
INPUT 1Ay-z PRI [pri]
where y is the slot number, z is the port number, and [pri] is the priority value.
Repeat this command for each port and each slot.
TL1 commands:
SET-PRMTR-INPUT::S1Ay[-z]:123::ON,[pri];
where y is the slot number and z is the port number. This command sets the
Priority to the value (1–10) you enter. Repeat this command for each port and slot.
SET-PRMTR-CCINP::S1Ay[-z]:123::ON,[pri];
for Composite Clock Input modules, This command enables the module (y) and
port (z) and sets its Priority to the value (1–10) you enter. Repeat this command
for each CC Input port and slot.
4. Disable all slots and/or ports with no connected input signal to prevent spurious
alarms.
ICS command:
Type
INPUT 1Ay-z DISABLE
is the port number. Repeat this command for each unused slot and port.
TL1 command:
SET-PRMTR-INPUT::S1Ay[-z]:123::OFF;
where y is the slot number and z is the port number. Repeat this command for
each unused slot and port.
12713020-002-2 Revision F.01 – January 2007
Chapter 3 Provisioning and Operating the SSU-2000
Logging In to the
, then press Enter
, then press Enter
then press Enter, where y is the slot number and z
Initial Provisioning
SSU-2000, on
SSU-2000 User's Guide 109