Configuration Options; Japanese Sine Wave Input Module Status Led Indicators; Japanese Sine Wave Input Module Configuration Settings - Symmetricom SSU-2000 User Manual

Synchronization supply unit and synchronization distribution unit
Hide thumbs Also See for SSU-2000:
Table of Contents

Advertisement

Chapter 7 Input Module Reference Data
Japanese Sine Wave Input Module
Table 7-13. Japanese Sine Wave Input Module Status LED Indicators
Indicator
POWER
Green
STATUS
Green/Amber
PORT 1 REF
Green
PORT 1 INPUT
Green/Amber
PORT 2 REF
Green
PORT 2 INPUT
Green/Amber
PORT 3 REF
Green
PORT 3 INPUT
Green/Amber

Configuration Options

The configuration settings for the Japanese Sine Wave Input module are listed in
Table
7-14.
Table 7-14. Japanese Sine Wave Input Module Configuration Settings
Configuration Setting
Input Frequency
(for unframed signals)
Provisioned PQL
Priority
FREQ Set ClkA
FREQ Set ClkB
FREQ Clear ClkA
FREQ Clear ClkB
192 SSU-2000 User's Guide
Color
On = The module is receiving +5 V DC
Off = +5 V DC not present on the module
On (Green) = Unit is in Normal mode of operation; no faults
On (Amber) = Fault condition detected
Blinking = Disabled or firmware upgrade in progress
On = Selected Reference
Off = Disabled, or good and not selected
On (Green) = Enabled and signal valid
On (Amber) = Enabled and signal not valid
Off = Disabled
On = Selected Reference
Off = Disabled, or good and not selected
On (Green) = Enabled and signal valid
On (Amber) = Enabled and signal not valid
Off = Disabled
On = Selected Reference
Off = Disabled, or good and not selected
On (Green) = Enabled and signal valid
On (Amber) = Enabled and signal not valid
Off = Disabled
Factory Default
6.312 MHz
4
1
16000
16000
12000
12000
Description
Range
1.544 MHz | 6.312 MHz
1 to 16
0 to 10, 0 is Monitor
0 to 10 000 000
0 to 10 000 000
0 to 10 000 000
0 to 10 000 000
12713020-002-2 Revision F.01 – January 2007

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sdu-2000

Table of Contents