Promax HD RANGER+ Manual page 163

Tv & satellite analyser
Hide thumbs Also See for HD RANGER+:
Table of Contents

Advertisement

Name
Description
Question
Response
April 2013
MEASURE
It provides information of all active measurements
*?MEASURE measure
*MEASURE measure=measure_resp units
measure
<empty>
POWER
LEVEL
C/N
V/A
MER
CBER
VBER
LBER
LM
=
<
>
units
dB
dBm/dBuV/dBmV
Description measure_resp
All the active measures
Digital channel power
Analogue channel level
C/N of the measured channel (dB)
Video/Audio carrier ratio
MER measurement value
CBER measurement value
VBER measurement value
LBER measurement value
Link Margin value
Measurement within scale
Measurement under the value shown
Measurement over the value shown
Description units
Measurement units for C/N, V/A, MER
Measurement units for POWER, LEVEL
45