  • Page 1 CABLE RANGER CABLE RANGER FIBER-COAXIAL DOCSIS ANALYZER -0 MI2177 -...
  • Page 2 SAFETY NOTES Read the user’s manual before using the equipment, mainly "SAFETY RULES" paragraph. The symbol on the equipment means "SEE USER’S MANUAL". In this manual may also appear as a Caution or Warning symbol. WARNING AND CAUTION statements may appear in this manual to avoid injury hazard or damage to this product or other property.
  • Page 3 SAFETY RULES * The safety could not be assured if the instructions for use are not closely followed. * Use this equipment connected only to systems with their negative of measurement connected to ground potential. * The AL-103 external DC charger is a Class I equipment, for safety reasons plug it to a supply line with the corresponding ground terminal.
  • Page 4 SAFETY SYMBOLS DESCRIPTIVE EXAMPLES OF OVER VOLTAGE CATEGORIES * Cat I: Low voltage installations isolated from the mains. * Cat II: Portable domestic installations. * Cat III: Fixed domestic installations. * Cat IV: Industrial installations. CAUTION: The battery used can present danger of fire or chemical burn if it is severely mistreat.
  • Page 5: Table Of Contents

    TABLE OF CONTENTS 1. INTRODUCTION ..................1 1.1. Description .................... 1 2. SETTING UP ....................4 2.1. Package Content ..................4 2.2. Power ....................4 2.3. Equipment Details .................. 7 2.4. Switching On / Off .................. 9 2.5. Icons Table ..................10 2.6.
  • Page 6: Introduction

    FIBER-COAXIAL DOCSIS ANALYZER CABLE RANGER 1 INTRODUCTION Description RANGER is the latest introduction in our CATV analyzer product CABLE range. It is an hybrid analyzer (for both fibre optics and coaxial cable) for the installation, configuration and maintenance of interactive video and data services at high speed over TV networks based on the DOCSIS standard.
  • Page 7 The main difference between CABLE RANGER CABLE RANGER is that the 3.1 model has an OFDM demodulator that allows you to demodulate DOCSIS 3.1 channels. These channels are made of thousands of narrow bandwidth subcarriers. Figure 1. The Spectrum Analyzer function provides an analysis of the full band and allows changing the reference level and the span among others.
  • Page 8 The Voltage Input function automatically identifies the type of voltage (continuous or alternating) at the input, the voltage and displays the output current. The Optical Power Meter function measures the optical power and other RFoG (Radiofrequency-over-Glass) measurements. In addition, it includes other tools such as datalogger, screenshot, channel plan editor, etc.
  • Page 9: Setting Up

    2 SETTING UP Package Content Check that your package contains the following elements: RANGER Analyser. CABLE External DC charger. Power cord for external DC charger Car lighter charger. "F" Adapters •"F" / f - BNC / f Adapter. (2 u.). •"F"...
  • Page 10 2.2.2 Charging the Battery Connect the DC power adapter to the equipment through the power connector on the left side panel (see figure). Figure 2. Then connect the DC power adapter to the mains via the mains cord. Ensure that your mains voltage is compatible with the adapter voltage.
  • Page 11 Usage Tips The battery is losing storage capacity as you go through its life. Contact your PROMAX distributor when necessary to replace the battery. To prolong battery life the user should follow these tips: In case of providing a long inactivity period of the equipment it is advisable to make every 3 months a charge / discharge cycle and a subsequent partial charge (40% aprox.).
  • Page 12: Equipment Details

    Equipment Details Figure 3. Front View. Chapter 2: SETTING UP March 2020...
  • Page 13 Figure 4. Side View. March 2020 Chapter 2: SETTING UP...
  • Page 14: Switching On / Off

    Figure 5. Top View. Switching On / Off Switching On: ► Press the on/off button located on the side of the equipment. The boot screen appears. After the system load, the last screen before shutdown appears. Switching Off: ► There are two options : Option 1: Press the on/off button located on the side of the equipment.
  • Page 15: Icons Table

    screen with a red power off icon will appear. Click on this icon to turn off the equipment or outside the icon to cancel power off. The equipment keeps its last status which is recovered when power on . Icons Table Figure 6.
  • Page 16: Icons Table

    Access to datalogger (test&go). Power energy for RF. Access to measurement options for RF. Icons Table On the screen it may appear some icons, which give extra information about the meter status or functions. Figure 7. Controls The equipment can be fully operated using the touch panel.. Chapter 2: SETTING UP March 2020...
  • Page 17: General Settings

    These actions can be done through the touch panel: Menu Selection. Frequency or channel selection. Frequency or channel scroll. Reference level scroll. SPAN selection. Virtual keyboard writing (numerical and alphabetical). General Settings From the Home screen, clicking on the menu icon you Access General Settings: Edit channel plan: It allows you to edit a channel plan (refer to "Edit...
  • Page 18 To update your meter firmware please contact PROMAX: https://www.promaxelectronics.com/ing/contact-promax/ Chapter 2: SETTING UP March 2020...
  • Page 19: Measurement

    3 MEASUREMENT Spectrum Analyzer (cable & FO) Description ► The SPECTRUM ANALYZER function shows on screen the spectrum of the signal received through the input connector. This function shows signals in frequency band so user can detect any problem and also measures level and demodulates signal. User can select span and reference level by selecting a frequency or channel.
  • Page 20 Screen Description ► Figure 8. Selection of tune mode: Channel/frequency/DBG. The selected tune mode is highlighted. From left to right are: Channel tuning: It shows the selected channel, channel plan and signal type (digital/analogue). When pressing on it deploys a list of available channels.
  • Page 21 Bandwidth resolution. Arrows to increase / decrease span. Current span. Span lower frequency. Arrows to change reference level. Description of Signal Demodulation Screen ► Figura 9. Demodulated Signal. Measurement obtained from signal demodulation (for more details refer to “Demodulator” on page 56).
  • Page 22: Scan (Cable & Fo)

    : It comes back to the last screen. Settings ► Click on the MENU icon at the upper right corner to access the Settings menu. The SPECTRUM ANALYZER function has these options: Edit channel plan: It allows you to edit a channel plan and DBG (refer to "Edit Channel Plan"...
  • Page 23 Select SCAN function according to input signal (cable or fiber). Press function on the left side of the screen for FIBER OPTICS or on the right side for CABLE. SCAN function opens. Press SYSTEM to demodulate signal and show constellation. To quit press HOME key.
  • Page 24 Measurement of the selected channel: Channel power and MER (for digital channel) / Level (for analogue channel). System measurement: It shows the demodulation system for the channel/ frequency selected. When pressing on it, it shows the data obtained after signal demodulation for digital channels or additional measurements for analogue signals.
  • Page 25: Tilt (Cable & Fo)

    Options Menu ► There are some options at the bottom of the screen: : Screenshot. DATALOGGER: It creates a datalogger with measurement data. DBG: It accesses the DBG function that shows the channels belonging to the Docsis Bonding Group and also demodulates the selected channel. TILT: It accesses the TILT function (for more details see next).
  • Page 26 therefore readjust equalizers of the amplifiers in order to compensate these losses and ensure a flat response along the band. Operation ► Connect signal to input connector: Cable: universal connector for F/F or F/BNC adapter. Fiber Optics: SC-APC connector. Access home screen by pressing the HOME key.
  • Page 27 Screen Description ► Figure 12. P1 - P4: Pilot signals. It shows pilot signal frequency and power. Press on frequency to change its value. TILT: Inclination rate in dB per MHz and power difference between P1 and Bar graph showing signal level for each pilot signal and TILT. Arrows to change reference level.
  • Page 28: Satellite (Cable & Fo)

    Click on the MENU icon at the upper right corner to access the Settings menu. The TILT function has these options: Units: It allows you to select a measurement unit for power (dBuV, dBmV, dBm). SATELLITE (cable & FO) Description ►...
  • Page 29 Screen Description ► Figura 13. Selection of tune mode: Channel/frequency. The selected tune mode is highlighted. From left to right are: Channel tuning: It shows the selected channel, channel plan and signal type (digital/analogue). When pressing on it deploys a list of available channels.
  • Page 30 Description of Signal Demodulation Screen ► Figura 14. Demodulated Signal. Measurement obtained from signal demodulation (for more details refer to “Demodulator” on page 56). Options Menu ► There are some options at the bottom of the screen: : Screenshot. CLEAR: It clears spectrum trace (this options is available if trace was hold previously).
  • Page 31: Cable Modem

    Edit channel plan: It allows you to edit a channel plan and DBG (refer to "Edit Channel Plan" chapter). Units: It allows you to select measurement unit for power (dBuV, dBmV, dBm). Reference line: It allows you to select the reference line by numbers 60 dBmV to +70 dBmv).
  • Page 32 The SCAN CM function shows on screen signal level in graphic bar format for each one of the active channels in the cablemodem band. RANGING (also known as a CABLE MODEM EMULATOR) is a tool to adjust transmission parameters at the CM, such as frequency and power in order to get a stable and aligned communication between CM and CMTS.
  • Page 33 3.5.1 (cable & FO) DS SPECTRUM Description ► DS SPECTRUM function shows signal spectrum in the Downstream band. Screen Description ► Figure 15. Selection of tune mode: Channel/frequency/DBG. The selected tune mode is highlighted. From left to right are: Channel tuning: It shows the selected channel, channel plan and signal type (digital/analogue).
  • Page 34 System measurement: It shows the demodulation system for the channel/ frequency selected. When pressing on it, it shows the data obtained after signal demodulation for digital channels or additional measurements for analogue signals. Marker for selected channel / frequency. Bandwidth of the selected channel is delimited by two continuous and vertical lines.
  • Page 35 Filter: It allows you to define the frequency filter (230 kHz, 2 MHz or Auto). Tuning frequency demodulation: It allows you to set parameters to demodulate tuned frequency. User must select bandwidth, type of signal (digital, analogue, FM or continous wave) and other related parameters according to signal.
  • Page 36 Constellation Diagram and measurements for the channel pointed by the marker. Options Menu ► There are some options at the bottom of the screen: : Screenshot. DATALOGGER: It creates a datalogger with measurement data. SPECTRUM: It returns to the DOCSIS DOWNSTREAM SPECTRUM ANALYZER function (see previous section).
  • Page 37 Screen Description ► Figure 17. Selection of tune mode: Channel/frequency/DBG. The selected tune mode is highlighted. From left to right are: Channel tuning: It shows the selected channel, channel plan and signal type (digital/analogue). When pressing on it deploys a list of available channels.
  • Page 38 Bandwidth resolution. Arrows to increase / decrease span. Current span. Span lower frequency. Arrows to change reference level. 3.5.4 RANGING (cable) Description ► The RANGING function (also called CABLEMODEM emulation) connects internal CABLEMODEM of the equipment to CMTS and generates an UPSTREAM signal. Tune a carrier from SPECTRUM or DBG then press RANGING to connect to CMTS.
  • Page 39 MER: Modulation Error Ratio. PreBER: Error ratio before correction. PostBER: Error ratio after correction. Interleaver: Improvement of error correction performance. Offset: Offset for tuning frequency. Downstream (OFDM modulation) ► System: Transmission standard. Frequency PLC: PLC channel frequency. FFT Size: Amount of subcarriers. PLC MER: MER of PLC channel.
  • Page 40 BACK: It comes back to the DS SPECTRUM. 3.5.5 REGISTERING (cable) Description ► It is necessary to register your equipment in the CMTS network to access functions to check VoIP, IPTV and Speed. When registering, Bonding Downstream, OFDM Downstream and Upstream features are shown on screen and also some info about the network.
  • Page 41 Upstream UC: Upstream Channel. F: Frequency (MHz). PWR: Power (dBmV). ATT: Channel attenuation (dB). SR: Symbol Rate (ksymps). Speed (bits/s). IP Report Cable Modem: IP for cable modem. Gateway: Gateway IP. Netmask. DHCP Server: IP for DHCP server. TFTP Server: IP for file transfer server. Options Menu ►...
  • Page 42 3.5.6 IPTV (cable) Description ► The IPTV test function performs an analysis of quality parameters for this type of service. The optimization of these parameters guarantees the best quality of service. In addition, knowledge of network conditions is important to install and fix other problems.
  • Page 43 Options Menu ► There are some options at the bottom of the screen: : Screenshot. REGISTERING: It returns to the REGISTERING function (see previous section). VoIP: It opens TEST VoIP function (see next section). SPEED: It opens TEST SPEED function (see next section). Settings Menu ►...
  • Page 44 Screen Description ► Figure 21. Enter the IP address to test and press SEND. Press STOP to stop the test. It shows values obtained during test. PLR (Packet Loss Rate): Percentage of lost packets over total sent packets. R VALUE: It shows a number or score, that is used to quantitatively express the subjective quality of speech in communications systems.
  • Page 45 IPTV: It opens IPTV function (see next section). SPEED: It opens TEST SPEED function (see next section). Settings Menu ► Click on the MENU icon at the upper right corner to access the Settings menu. The VoIP function has these options: PING Settings: •PING data length.
  • Page 46: External Cm / Upstream Spectrum (Cable)

    Press START to start the speed test. It measures download and upload channel speed. It also gets some data from the service provider. Options Menu ► There are some options at the bottom of the screen: : Screenshot. REGISTERERING: It returns to the REGISTERING function (see previous section).
  • Page 47 Screen Description ► Figure 23. Frequency selected. When pressing on it pops up a virtual numeric keypad to edit frequency. Power level at selected frequency. Span upper frequency. Bandwidth resolution. Arrows to increase / decrease span. Current span. Span lower frequency. Arrows to change reference level.
  • Page 48: Upstream Test (Cable)

    Settings Menu ► Click on the MENU icon at the upper right corner to access the Settings menu. The EXT. CM / UPSTREAM function has these options:. Units: It allows you to select measurement unit for power (dBuV, dBmV, dBm). Reference line: It allows you to select the reference line by numbers (- 60 dBmV to +70 dBmv).
  • Page 49 Screen Description ► Figure 24. Parameters to set UPSTREAM signal: Docsis mode: To select Docsis mode. Frequency mode: Select between Sweep or Fix. Frequency start: Select start frequency (only for Sweep mode). Frequency stop: Select stop frequency (only for Sweep mode). Frequency: Select frequency (only for Fix mode) Power: Select power level for signal.
  • Page 50: Input Voltage (Cable)

    Units: It allows you to select measurement unit for power (dBuV, dBmV, dBm). Input Voltage (cable) Description ► The INPUT VOLTAGE function automatically identifies the voltage type (DC or AC) at the input, voltage and frequency in case of alternating current. Operation ►...
  • Page 51: Optical Power Meter (Fo)

    Settings Menu ► Click on the MENU icon at the upper right corner to access the Settings menu. The INPUT VOLTAGE function has these options: Units: It allows you to select measurement unit for power (dBuV, dBmV, dBm). Optical Power Meter (FO) Description ►...
  • Page 52 Screen Description ► Figure 26. Calibration used: Select wavelength for power measurement. O-PWER: Graphical bar and value of optical power with high and low threshold. Threshold values can be selected on settings menu. RF-PWR: Graphical bar and value of RF power . Relative Power: Graphical bar and value of power signal loses.
  • Page 53 Define optical thresholds: It allows you to define, select and save sets of threshold values (up to 8 sets). The selected set is shown at the lower screen next to the reference. March 2020 Chapter 3: MEASUREMENT...
  • Page 54: Tools

    4 TOOLS Edit Channel Plan Description ► Channel plan editor allows to edit and create channel plans, and also to edit DBG (Docsis Bonding Group) channels. Operation ► Channel plan editor is available for SPECTRUM ANALYZER, SCAN/TILT, SATELLITE and CABLE MODEM. Select channel plan on main screen.
  • Page 55 Screen Description ► Figure 27. Channel plan selected. Press on this box to select another channel plan. Go to: Press on this box to switch between CH (channel) and FR (frequency) and to select a channel or frequency. Channel table. Parameters on channel table are: CH: Channel.
  • Page 56 Options Menu ► There are some options at the bottom of the screen: EDIT DBG: Opens the DBG editor screen (see next section. : Back to main screen. Settings Menu ► Click on the MENU icon at the upper right corner to access the Settings menu.
  • Page 57 EDIT DOCSIS BONDING GROUP Screen Description ► Figure 28. Edit Docsis Bonding Group: Press on the box to select DBG to edit. Add channel to DBG: Press on arrows or on the box to select one channel and then press on ADD to add to DBG. Remove channel to DBG: Press on arrows or on the box to select one channel and then press on REMOVE to remove from DBG.
  • Page 58 Create a Channel Plan from an existing one ► Figure 29. Figure 30. Press on box "Model" to select a channel plan as a model to create a new one. Press on box "Name" to give a name to the new channel plan. Chapter 4: TOOLS March 2020...
  • Page 59 Press "OK" to create a new channel plan or "Cancel" to exit. At the next screen, press on "Add Channel", "Remove Channel" to edit channel plan. When finish, press on "Save channel plan" to save changes or "Cancel" to exit without saving. Create automatically a channel plan from HFC network ►...
  • Page 60 Figure 32. Connect to the HFC network. Press on box “Model” to select a channel plan as a model to create a new one. Press on “Start measuring”. When finish press on "Name" box to edit the channel plan name. Press on "Save channel plan"...
  • Page 61: Demodulator

    Create a new Channel Plan from scratch ► Figure 33. Press on box "Name" to give a name to the new channel plan. At the next screen, press on “Add Channel”, “Remove Channel” to edit channel plan. When finish, press on “Save channel plan” to save changes or “Cancel”...
  • Page 62 Operation ► available digital signals functions SPECTRUM DEMODULATOR ANALYZER and SCAN Select channel or frequency and tune it. Press on "SYSTEM" option. Screen Description ► Figure 34. Demodulated Signal Data. MER for tuned channel. pre-BER (BER before correction). post-BER (BER after correction). Transmission standard.
  • Page 63: Analog Video Carrier / Hum

    Options Menu ► There are some options at the bottom of the screen: CLR IQ: It clears constellation . Back to previous screen. Analog Video Carrier / HUM Description ► The equipment can measure video carrier signal level, Video/Audio and C/N ratio and HUM in analog mode.
  • Page 64: Screenshot

    Screen Description ► Figure 35. Analogue Video Carrier / HUM. Vídeo c.LVL: Level of video carrier. Audio c.LVL: Level of audio carrier. V/A: Video/Audio ratio. C/N: Carrier/Noise ratio. HUM: Audio carrier. CTB/CSO: Intermodulation product measurement. Audio OFF/ON: It enables / disables audio and to set audio level. Screenshot Description ►...
  • Page 65 Operation ► Figure 36. Screenshot is available almost all functions. To take a screenshot press on photo camera icon at the lower left corner. It pops up a window with a screenshot miniature and some options: “Save and close”, “Save and go to gallery” and “Cancel”. Press your option. To access the photo gallery with all the screenshots, from home screen press on icon at the lower left corner.
  • Page 66: Datalogger

    To remove a single screenshot, see the screenshot fullscreen, press on option menu and then on “Remove” and confirm. Datalogger Description ► Datalogger function can logger automatically several measurements depending on the selected function, including signal level and channel power, carrier/noise, BER and MER for all channels in a specific channel band.
  • Page 67 To access datalogger, go to home screen and press on icon at the lower left corner. Datalogger are classified by function. Press on any folder, then press on the datalogger to see data. To remove a folder with dataloggers or a single datalogger, press on the menu option and then on “Remove”.
  • Page 68: Webcontrol

    5 WEBCONTROL Introduction The webControl function allows you to connect remotely to the meter in order to visualize measurements and operate on it. The meter must be connected to an Ethernet network. To connect to meter from a remote access device use just a standard web browser.
  • Page 69 Figure 38. Enter the password and press OK (password by default is Password). NOTE: If you have follow these instructions and you fail to connect the webControl, please contact PROMAX technical assistance and we will help you (promax@promax.es). Password Recovery ►...
  • Page 70: File Management

    Contact details: Full name, company name and address, phone number and e-mail. Internal number shown on the window. Recovery code shown on the window. Once this information is sent, it is checked and if everything is right, a temporary password is sent back. Write this password on the box “temporary password”.
  • Page 71 The padlock icon on an item means that it cannot be removed. If the padlock is on a folder it also means that its content cannot be change (nor deleted or added). To make any action on an item use the tools bar or deploy the options menu by pressing the right button of the mouse.
  • Page 72 Create archive: It creates a zip file from the files selected in TAR or GZIP format. Extract files from archive: It unzips a zipped file in a new folder or in the current folder. Select All: It selects all the files. Invert selection: It reverts the current selection.
  • Page 73 Channel Plan Creator Operation ► Press on the “Channel Plan” tab to access the channel plan creator. Press on “Create Channel Plan” button. In the box “Name” enter the channel plan name. Press the “Add Channel” button and enter one by one each channel that made the channel plan.
  • Page 74 Channel Plan Editor Operation ► Files with channel plans are inside the “ChannelPlans” folder. Select the file that contains the channel plan to edit and press the right button on the mouse to select the “Edit channel plan” option. The channel plan definition parameters and all the channels that form it will appear.
  • Page 75: Specifications

    6 SPECIFICATIONS Spectrum Analyzer ►Frequency Parameter Value Additional Data Tuning Range From 5 to 1700 MHz 1200 MHz/ DOCSIS, 1700 MHz/DOCSIS 3.1 Tuning Mode By Frequency or by channel Bandwidth resolution 230 kHz, 2 MHz Frequency step 10 KHz Accuracy 20 ppm Sweep time 600 ms full band...
  • Page 76 Parameter Value Additional Data Pre BER (Before RS): From 10 E-2 to Post BER (After FEC): From 10 E-2 to 10 E-10 10 E-10 Constellation Diagram For all systems with x2, x4 zoom Lock range -20 dBmV to 60 dBmV ►Measurements: Analog Channel Demodulation Parameter Value...
  • Page 77 ►Amplitude Parameter Value Additional Data Dynamic range -50 dBmV to 60 dBmV Screen range 50 dB Max Input level 70 dBmV Resolution 0.1 dB Accuracy ± 2 dB Input impedance 75 Ohms Units dBmV, dBuV, dBm ►Measurements: Digital Channel Parameter Value Additional Data Power...
  • Page 78 ►Configuration Menu Parameter Value Additional Data Channel Plan Standard TV Channel plans CCIR,EIA,HRC,IRC,OIRL,FCC up to 10 Customized Channel plan Up to 30 Units dBmV, dBuV, dBm Reference Line from –60 dBmV to 120 dBmV Units dBmV, dBuV, dBm Reference Line from –60 dBmV to 120 dBmV Thresholds Max and Min limits for quality...
  • Page 79 ►Configuration Menu Parameter Value Additional Data Units dBmV, dBuV, dBm Select two pilots for Tilt P_bottom / P_top DOCSIS Analyzer ►Frequency Parameter Value Additional Data Tuning Range From 90 to 1700 MHz Tuning Mode By Frequency or by channel Frequency step 10 KHz Bandwidth resolution 230 kHz, 2 MHz...
  • Page 80 ►Downstream DOCSIS Channel Demodulation Parameter Value Additional Data Systems compatibility DOCSIS 2.0, DOCSIS 3.0 From 27 dB to 40 dB Pre BER (Before RS): From 10 E-2 to Post BER (After FEC): From 10 E-2 to 10 E-10 10 E-10 Constellation Diagram For all systems with x2, x4 zoom Lock range...
  • Page 81 Parameter Value Additional Data Level accuracy ±3 dB Modulation QPSK, 16QAM, 32QAM, 64QAM From 160 ksym/s to 5120 ksym/s ►Frequency (only for CABLE RANGER 3.1) Parameter Value Additional Data Mode OFDM 4K (DOCSIS 3.1) Bandwidth 100 MHz Tuning range From 5 to 204 MHz Carriers level From 50 to 120 dBuV (1 step dB) Accuracy level...
  • Page 82 ►Settings Parameter Value Datos Adicionales Trace Max hold and min hold Upstream band Docsis 2.0 upstream band/ Docsis 3.0 upstream band Channel bandwidth CW, 5 MHz, 7 MHz or selectable Input Voltage and RF Power Meter ►RF Power Measurement Parameter Value Additional Data Frequency band...
  • Page 83 ►Optical to RF Converter Parameter Value Additional Data Optical band 1100 nm – 1700 nm (Optical band pass filter as especial option) RF band 45 MHz to 1700 MHz Dynamic range -15 dBm to 10 dBm Operation RF from optics internally redirect TO SPECTRUM ANALYZER, SCAN, TILT and DOWN stream DOCSIS analyzer General Specifications...
  • Page 84 Parameter Value Additional Data Max. Relative Humidity 80 % up to 31ºC, decreasing lineally up to 50% at 40ºC NOTE: Equipment specifications are set in these environmental operating conditions. Operation outside these specifications are also possible. Please check with us if you have specific requirements. ►Included Accesories Parameter Value...
  • Page 85: Maintenance

    7 MAINTENANCE Instructions for Returning by Mail Instruments returned for repair or calibration, either within or out of the warranty period, should be sent with the following information: Name of the Company, name of the contact person, address, telephone number, receipt (in the case of coverage under warranty) and a description of the problem or the service required.
  • Page 86 Cleaning the Plastic Case ► The equipment has to be disconnected before cleaning the case. The case must be cleaned with a solution of neutral soap and water, using a soft cloth dampened with this solution. Before use, the equipment has to be completely dry. Never clean with abrasive soaps, chlorinated solvents or aromatic hydrocarbons.
  • Page 87 PROMAX ELECTRONICA, S.L. Francesc Moragas, 71-75 08907 L’HOSPITALET DE LLOBREGAT (Barcelona) SPAIN Tel: 93 184 77 00 * Tel. Intl.: (+34) 93 184 77 02 Fax: 93 338 11 26 * Fax Intl.: (+34) 93 338 11 26 http://www.promaxelectronics.com e-mail: promax@promaxelectronics.com...

This manual is also suitable for: