Modem/Configurable Pin Settings (3) (Make sure these settings match those
shown in Section 6.2.1.)
CAUTION! You must configure this setting correctly in order to be able to use the
Network Module Hardware Initialization procedure (Section 6.4).
Press 3. The following appears on the screen:
CP0 Function (hit space to toggle) GPIO (In)
Press the Space bar until the following appears on the screen:
CP0 Function (hit space to toggle) Defaults(In)
Press Enter. The following appears on the screen:
Invert (active low) (Y) ?
Press Y.
Ignore other settings (press Enter through the rest of Setting 3).
Advanced Modbus Protocol settings (4) (Make sure these settings match
those shown in Section 6.2.1.)
Slave address (0 for auto, or 1..255 fixed otherwise) (0) ? 0
Allow Modbus Broadcasts (1=Yes 2=No) (2) ? 2
Use MB/TCP 00BH/00AH Exception Responses (1=No 2=Yes) (2) ? 2
Disable Modbus/TCP pipeline (1=No 2=Yes) (1) ? 1
Character Timeout (0 for auto, or 10-6950 msec) (50) 50
Message Timeout (200-65000 msec) (5000) 5000
Serial TX delay after RX (0-1275 msec) (0) 0
Swap 4x/0H to get 3x/1x (N) ? N
Local slave address for GPIO (0 to disable, or 1..255) (0) ? 0