Electro Industries Shark 100S Installation & Operation Manual page 132

Electronic submeter with wifi ethernet capability
Hide thumbs Also See for Shark 100S:
Table of Contents

Advertisement

Modbus Address
Hex
Decimal
Primary Energy Block
044B - 044C
1100 - 1101
W-hours, Received
044D - 044E
1102 - 1103
W-hours, Delivered
044F - 0450
1104 - 1105
W-hours, Net
0451 - 0452
1106 - 1107
W-hours, Total
0453 - 0454
1108 - 1109
VAR-hours, Positive
0455 - 0456
1110 - 1111
VAR-hours, Negative
0457 - 0458
1112 - 1113
VAR-hours, Net
0459 - 045A
1114 - 1115
VAR-hours, Total
045B - 045C
1116 - 1117
VA-hours, Total
Primary Demand Block (IEEE Floating Point)
07CF - 07D0
2000 - 2001
Amps A, Average
07D1 - 07D2
2002 - 2003
Amps B, Average
07D3 - 07D4
2004 - 2005
Amps C, Average
07D5 - 07D6
2006 - 2007
Positive Watts, 3-Ph, Average
07D7 - 07D8
2008 - 2009
Positive VARs, 3-Ph, Average
07D9 - 07DA
2010 - 2011
Negative Watts, 3-Ph, Average
07DB - 07DC
2012 - 2013
Negative VARs, 3-Ph, Average
07DD - 07DE
2014 - 2015
VAs, 3-Ph, Average
07DF - 07E0
2016 - 2017
Positive PF, 3-Ph, Average
07E1 - 07E2
2018 - 2019
Negative PF, 3-PF, Average
Primary Minimum Block (IEEE Floating Point)
0BB7 - 0BB8
3000 - 3001
Volts A-N, Minimum
0BB9 - 0BBA
3002 - 3003
Volts B-N, Minimum
0BBB - 0BBC
3004 - 3005
Volts C-N, Minimum
0BBD - 0BBE
3006 - 3007
Volts A-B, Minimum
0BBF - 0BC0
3008 - 3009
Volts B-C, Minimum
0BC1 - 0BC2
3010 - 3011
Volts C-A, Minimum
0BC3 - 0BC4
3012 - 3013
Amps A, Minimum Avg Demand
0BC5 - 0BC6
3014 - 3015
Amps B, Minimum Avg Demand
0BC7 - 0BC8
3016 - 3017
Amps C, Minimum Avg Demand
0BC9 - 0BCA
3018 - 3019
Positive Watts, 3-Ph, Minimum Avg Demand
0BCB - 0BCC
3020 - 3021
Positive VARs, 3-Ph, Minimum Avg Demand
0BCD - 0BCE
3022 - 3023
Negative Watts, 3-Ph, Minimum Avg Demand
0BCF - 0BD0
3024 - 3025
Negative VARs, 3-Ph, Minimum Avg Demand
0BD1 - 0BD2
3026 - 3027
VAs, 3-Ph, Minimum Avg Demand
0BD3 - 0BD4
3028 - 3029
Positive Power Factor, 3-Ph, Minimum Avg Demand
Electro Industries/GaugeTech
The Leader In Power Monitoring and Smart Grid Solutions
1
Description
Format
SINT32
0 to 99999999 or
0 to -99999999
SINT32
0 to 99999999 or
0 to -99999999
SINT32
-99999999 to 99999999 Wh per energy format
SINT32
0 to 99999999
SINT32
0 to 99999999
SINT32
0 to -99999999
SINT32
-99999999 to 99999999 VARh per energy format
SINT32
0 to 99999999
SINT32
0 to 99999999
FLOAT
0 to 9999 M
FLOAT
0 to 9999 M
FLOAT
0 to 9999 M
FLOAT
-9999 M to +9999 M
FLOAT
-9999 M to +9999 M
FLOAT
-9999 M to +9999 M
FLOAT
-9999 M to +9999 M
FLOAT
-9999 M to +9999 M
FLOAT
-1.00 to +1.00
FLOAT
-1.00 to +1.00
FLOAT
0 to 9999 M
FLOAT
0 to 9999 M
FLOAT
0 to 9999 M
FLOAT
0 to 9999 M
FLOAT
0 to 9999 M
FLOAT
0 to 9999 M
FLOAT
0 to 9999 M
FLOAT
0 to 9999 M
FLOAT
0 to 9999 M
FLOAT
0 to +9999 M
FLOAT
0 to +9999 M
FLOAT
0 to +9999 M
FLOAT
0 to +9999 M
FLOAT
-9999 M to +9999 M
FLOAT
-1.00 to +1.00
Doc# E145721
Units or
6
Range
Resolution
Wh per energy format
* Wh received & delivered always have
opposite signs
Wh per energy format
* Wh received is positive for "view as load",
delivered is positive for "view as generator"
Wh per energy format
* 5 to 8 digits
VARh per energy format
* decimal point implied, per energy format
VARh per energy format
* resolution of digit before decimal point =
units, kilo, or mega, per energy format
VARh per energy format
VAh per energy format
* see note 10
amps
amps
amps
watts
VARs
watts
VARs
VAs
none
none
volts
volts
volts
volts
volts
volts
amps
amps
amps
watts
VARs
watts
VARs
VAs
none
B: Modbus Map
#
Comments
Reg
read-only
2
2
2
2
2
2
2
2
2
Block Size:
18
read-only
2
2
2
2
2
2
2
2
2
2
Block Size:
20
read-only
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
MM-2