Installing The B140I Sata Cables - HPE ProLiant XL270d Gen9 User Manual

Accelerator tray
Table of Contents

Advertisement

19. Install the air baffle.
If the 4:1 riser signal cable or Smart Storage Battery are installed in the air baffle, reconnect the cables to
the risers. For more information, see "Installing the air baffle."
20. Install the access panel.
21. Install the server into the chassis.
22. Connect all peripheral cables to the server .
23. Power up the server .

Installing the B140i SATA cables

About this task
To install the component:
Procedure
1.
Back up all server data.
2.
Power down the server .
3.
Disconnect all peripheral cables from the server .
4.
Remove the server from the chassis.
5.
Place the server on a sturdy, level surface.
6.
Remove the access panel.
7.
Remove the air baffle.
8.
Connect the B140i SATA cables:
a. Connect the cables to the system board. Install the cables according to their labels as MB-SATA 1 or
MB-SATA 2. The labels are on both the cables and their connections.
b. Connect the cables to the drive backplane. Install the cables according to their labels as Mini-SAS 0
or Mini-SAS 1. The labels are on both the cables and their connections.
Installing the B140i SATA cables