IntesisBox
KNX - Daikin A.C. (SKY & VRV line)
Appendix A – Communication Objects Table
OBJECT
TOPIC
NUMBE
R
On/Off
0
Control_ On/Off
1
Control_ Mode
2
Control_ Mode Cool/Heat
3
Control_ Mode Cool & On
4
Control_ Mode Heat & On
5
Control_ Mode Auto
Mode
6
Control_ Mode Heat
7
Control_ Mode Cool
8
Control_ Mode Fan
9
Control_ Mode Dry
Control_ Mode +/-
10
Control_ Mode +/-
Control_ Fan Speed / 2 Speeds
Fan Speed
11
Control_ Fan Speed / 3 Speeds
Control_ Fan Speed / 2 Speeds
© Intesis Software S.L. - All rights reserved
This information is subject to change without notice
®
IntesisBox
is a registered trademark of Intesis Software SL
LENGT
NAME
H
DPT_NAME
1 bit
DPT_Switch
DPT_HVACContrMod
1 byte
1 bit
DPT_Heat/Cool
1 byte
DPT_Scaling
1 byte
DPT_Scaling
1 bit
1 bit
1 bit
1 bit
1 bit
1 bit
1 bit
DPT_UpDown
1 byte
DPT_Scaling
1 byte
DPT_Scaling
1 byte
DPT_Enumerated
DATAPOINT TYPE
FLAGS
DPT_I
R
W T U
D
1.001
W T
20.105
W T
e
1.100
W T
5.001
W T
5.001
W T
DPT_Bool
1.002
W T
DPT_Bool
1.002
W T
DPT_Bool
1.002
W T
DPT_Bool
1.002
W T
DPT_Bool
1.002
W T
DPT_Step
1.007
W
1.008
W
5.001
W T
5.001
W T
5.010
W T
URL
Email
tel
User's manual r1.0 eng
FUNCTION
0 - Off; 1-On
0 - Auto; 1 - Heat; 3 - Cool; 9 - Fan; 14 - Dry
0 - Cool; 1 - Heat
0% - Off; 0.1%-100% - On + Cool
0% - Off; 0.1%-100% - On + Heat
1 - Auto
1 - Heat
1 - Cool
1 - Fan
1 - Dry
0 - Decrease; 1 - Increase
0 - Up; 1 - Down
0%-74% - Speed 1; 75%-100% - Speed 2
0%-49% - Speed 1; 50%-83% - Speed 2;
84%-100% Speed 3
1 - Speed 1; 2 - Speed 2
http://www.intesis.com