Trim Gauge Test - Evinrude E-TEC E115DPLSCR Service Manual

E-tec series
Table of Contents

Advertisement

Monitor motor RPM and current draw.
The motor shaft must rotate clockwise, as viewed
from the pump end, when positive (+) is applied to
the blue lead, and negative (–) is connected to
green lead.
The motor shaft must rotate counterclockwise, as
viewed from the pump end, when positive (+) is
applied to the green lead, and negative (–) is
applied to the blue lead.
Blue lead (+)
Green lead (-)
If test results vary, replace the motor.

Trim Gauge Test

STEP 1
Turn key switch ON. Using a voltmeter, check for
voltage between the trim gauge "I" and "G" termi-
nals.
If no voltage, check condition of instrument har-
ness, key switch, and engine 20 A fuse.
If voltage, go to STEP 2.
30957
Green lead (+)
Blue lead (-)
STEP 2
Remove the white/tan lead from the trim gauge
"S" terminal. With key switch ON, gauge should
indicate full-trim DOWN position. Now connect a
jumper wire between terminals "S" and "G."
Gauge should indicate full-trim UP position.
DR4238r
If results are different, replace the trim gauge.
If results agree, refer to Trim Sender Test.
TRIM AND TILT
ELECTRICAL CIRCUIT TESTS
DRC6245
DRC6246A
14
373

Advertisement

Table of Contents
loading

Table of Contents