INSTALLATION AND PREDELIVERY

BOAT RIGGING

BOAT RIGGING

Remote Controls

Control Selection
WARNING
The remote control used must have start-
in-gear prevention. This feature can pre-
vent injuries resulting from unexpected
boat movement when the outboard starts.
Remote control and wiring harness options are
described in the Evinrude/Johnson Genuine Parts
and Accessories Catalog.
The remote control and wiring harness combina-
tion must have the following features:
Start-in-gear prevention
Emergency stop / key switch
Shift stroke must measure 1.125 to 1.330 in.
(28.6 to 33.8 mm) between NEUTRAL and
FORWARD
Throttle stroke must PUSH for open
Connections for engine monitor warning sys-
tem.
3
1. Emergency stop clip
2. Safety lanyard
3. Key switch with emergency stop feature
28
Dual-outboard controls require separate key
switches with a single emergency stop switch.
Dual-outboard key switches with emergency stop
switch
Always install and recommend use of an
emergency stop/key switch. Doing so will
reduce the risk of personal injury or death
should the operator fall away from the con-
trols or out of the boat.
Engine Monitoring System
IMPORTANT:
must be equipped with an I-Command system, a
SystemCheck gauge, or an equivalent engine
monitor. Operating the outboard without an
engine monitor will void the warranty for failures
related to monitored functions.
Refer to ENGINE MONITORING SYSTEM on
p. 101.
002817
WARNING
Outboards with remote controls
DRC40118