Oil Supply Vacuum Test - Evinrude E-TEC E115DPLSCR Service Manual

E-tec series
Table of Contents

Advertisement

Oil Supply Vacuum Test

WARNING
Wear safety glasses to avoid personal
injury, and set compressed air pressure to
less than 25 psi (172 kPa).
Remove the oil pick-up assembly from the oil tank.
Carefully remove the pickup filter and flush with a
mild solvent to remove any contamination. Rein-
stall filter.
Carefully remove the oil hose from the oil pickup
and remove the oil supply hose from the oil injec-
tion pump.
Use low pressure air to purge oil from hose.
1
2
1. Oil hose
2. Oil pickup
3. Low pressure air
Use Plug/Holder, P/N 329661, and clamp to plug
the pickup end of the hose.
1. Plug/holder
2. Oil hose
Attach a vacuum tester to the outboard side of oil
supply hose and draw 7 in. Hg (24 kPa) vacuum
on the hose for at least five minutes. Repair or
replace any leaking components. Reinstall the oil
hose.
Check height of pickup assembly.
Pickup Assembly Height
1.8 gallon tank
3.0 gallon tank
3
Height of Oil Pickup Assembly
Place a new seal on oil tank and reinstall pickup
with filter into oil tank. Install and tighten screws.
12306
2
1
12307
OILING SYSTEM
OILING SYSTEM TESTS
6.84 to 6.96 in.
(174 to 177 mm)
8.74 to 8.86 in.
(222 to 225 mm)
COB5657A
209
9