Ignition Voltage Test

Use the Evinrude Diagnostics software Monitor
screen to check ignition voltage to the primary
ignition circuits of the ignition coils.
Engine Monitor Screen, Ignition Voltage
Results:
KEY ON (not running) - 125 V ± 10, Ignition
voltage is GOOD, check voltage with outboard
running.
KEY ON (not running) - less than 125 V ± 10,
check system voltage to EMM. Refer to System
Voltage Test on p. 118. Note: Key ON voltage
will not be constant (fluctuates 125 - 200 V
range)
"RUNNING" - 200 V ± 10, Ignition voltage is
GOOD.
"RUNNING" - less than 200 V ± 10, check stator
output to EMM. Refer to System Voltage Test
on p. 118 and STATOR TESTS on p. 136
Low or no voltage on EMM ignition circuit:
Check system voltage (55 V) input to ignition
circuit on pin 4 of EMM J1-B connector.

Static Ignition Test

Perform the static ignition test using Evinrude
Diagnostics software and an inductive timing light.
IMPORTANT:
with E-TEC models. Radio Frequency Interfer-
ence (RFI) generated by the arcing current can
cause erratic behavior in the EMM.
The outboard must NOT be running and the emer-
gency stop switch lanyard must be installed.
006751
Static Tests Screen
Connect timing light pickup to the secondary cir-
cuit (spark plug lead) of the cylinder being tested.
Activate test and observe timing light strobe for
consistent flash.
2
1. Timing light pick-up
2. Spark plug lead
IMPORTANT:
ing from wire if pickup does not read signal.
SYSTEM ANALYSIS
IGNITION OUTPUT TESTS
DO NOT use a spark checker tool
You may need to remove shield-
6
006752
1
005319
119