Error Messages
Error 1050 - The Maint Cartridge is Full
A print job cannot start if the maintenance cartridge is full.
Solutions
Use the following solutions to troubleshoot the issue. The most likely solutions are listed first,
followed by other possibilities. Check to see if the issue is resolved after performing each
recommended solution. If the issue is not resolved, proceed to the next solution. If the issue
persists after performing all solutions, contact Technical Support.
1) Install a new maintenance cartridge.
2) Press and release the power key to clear the error.
3) If your printer model has a maintenance cartridge sensor, clean the sensor and the
108
maintenance cartridge. If ink is present on the sensor or the exterior of the maintenance
cartridge, false sensor readings may occur.
Open the lower side door and remove the maintenance cartridge. Use a clean, lint-free
cloth dampened with isopropyl alcohol to clean the optical sensor [1] inside printer.
[1]
QL-800 User Guide