Low Power Timeout
To extend laser life, you can select the length of time the scanner remains active following a
successful decode. The scanner wakes from low power mode when a bar code is scanned – a
successful decode restores normal blinking.
When you double-tap on this parameter, a dialog box is displayed in which you can choose a
value of 30 sec, 1 min, 2 min or 3 min.
Note: This parameter is only used if the Trigger Mode has been set to Continuous On and
the EP10 is mounted in a fixed position; otherwise, 'Low Power Timeout' is not
used.
Parameter Scanning
Setting this parameter to Enabled allows decoding of parameter bar codes.
Same Read Validate
The data is only transmitted after repeated reads give the same result. The
value assigned at this parameter determines the number of reads required, from
0 to 10 times.
Same Read Timeout
Prevents the same bar code from being read more than once. The value assigned determines
after what time period the scanner will timeout, from 0 to 2550 msec.
Diff Read Timeout
Prevents unwanted reading of other bar codes on the same label. The value assigned deter-
mines after what time period the scanner will timeout, from 0 to 2550 msec.
Add AIM ID Prefix
The AIM ID (Association for Automatic Identification and Mobility) is an international bar
code identifier. When this parameter is enabled, the AIM ID is inserted at the beginning of
the decoded bar code.
C.3.3

Code 39

Enable
Setting this parameter to on enables "Code 39".
Preliminary Draft
EP10 Hand-Held (Windows Embedded 6.5) User Manual
Appendix C: Bar Codes Settings
Code 39