Electrical system
ACTIVATION AND MAINTENANCE
Remove the battery from the vehicle.
Remove the cell caps and the breather cap.
Fill the cells with electrolyte fluid with 1.3 specific weight.
Charge the battery with a slow charge (current rating equal to 1/10 of the battery capacity)
for at least 10 hours: Refit battery to the motorcycle upon delivery to customer, that is to say,
when a mileage is set.
Install the battery on the motorcycle, connect the leads and the breather pipe.
If the motorcycle is not used for a long period, it is necessary to recharge it periodically (at
least once a month) for at least 10 hours (for instance, during the long winter break).
Periodically (once a month) restore the electrolytic fluid level only with distilled water.
Connectors
ECU
key:
- Injection warning light LED (Pin 1)
- Rpm indicator on the instrument panel (Pin 2)
- CAN line "L" (Pin 3)
- Lambda probe "S-" (Pin 4)
- Live (Pin 5)
- Battery-powered (Pin 6)
- Immobiliser aerial (Pin 7)
- Fan relay (Pin 8)
- Water temperature sensor (Pin 9)
- CAN line "H" (Pin 10)
- Lambda probe "S+" (Pin 11)
ELE SYS - 86