Electrical system
ACTIVATION AND MAINTENANCE
•
Remove the battery from the vehicle.
•
Remove the cell caps and the breather cap.
•
Fill the cells with electrolyte fluid with 1.3 specific weight.
•
Charge the battery with a slow charge (current rating equal to 1/10 of the battery capacity)
for at least 10 hours: Refit battery to the motorcycle upon delivery to customer, that is to say,
when a mileage is set.
•
Install the battery on the motorcycle, connect the leads and the breather pipe.
•
If the motorcycle is not used for a long period, it is necessary to recharge it periodically (at
least once a month) for at least 10 hours (for instance, during the long winter break).
•
Periodically (once a month) restore the electrolytic fluid level only with distilled water.
Connectors
ECU
key:
- Injection warning light LED (Pin 1)
- Rpm indicator on the instrument panel (Pin 2)
- CAN line "L" (Pin 3)
- Lambda probe "S-" (Pin 4)
- Live (Pin 5)
- Battery-powered (Pin 6)
- Immobiliser aerial (Pin 7)
- Fan relay (Pin 8)
- Water temperature sensor (Pin 9)
- CAN line "H" (Pin 10)
- Lambda probe "S+" (Pin 11)
ELE SYS - 86