Electrical system
9. HV coil
- Coil primary resistance: 0.5 Ohm ± 8%
- Coil secondary resistance: 3.1 Ohm ± 9%
10. Voltage regulator
- Recharging voltage: 13-15 V
- No-load voltage at terminals: 45 V
11. Start-up relay
- Relay voltage, powered: 0 Ohm
- Relay voltage, not powered: endless
12. Water Temperature Sensor
COOLANT TEMPERATURE °C (°F) - RESISTANCE VALUE (OHM)
Specification
-10° (14°)
0°(32°)
10° (50°)
20°(68°)
30°(86°)
ELE SYS - 62
ATLANTIC 300 i.e.
Desc./Quantity
9.6 kOhm
5.975 kOhm
3.81 kOhm
2.5 kOhm
1.68 kOhm