ATLANTIC 300 i.e.
- Measure the diameter of the valve stem at the
three positions indicated in the diagram.
Specification
Outlet:
Specification
Outlet:
- Calculate the clearance between the valve and its guide.
- Check the deviation of the valve stem by resting
it on a «V» shaped support and measuring the ex-
tent of the deformation using a dial gauge.
Characteristic
Limit value allowed:
0.1 mm
STANDARD DIAMETER
Inlet:
MINIMUM DIAMETER ALLOWED
Inlet:
Characteristics
Desc./Quantity
4.987 ÷ 4.972 mm
4.975 ÷ 4.960 mm
Desc./Quantity
4.96 mm
4.945 mm